Email verifiedBusiness License verified

FL SWITCH 3006T-2FX - Industrial Ethernet Switch

2024-05-11T01:57:54Z 
Company: 上海当临自动化科技有限公司
Location: China - Shanghai,上海市青浦区练西公路2850号1幢
Price: Negotiation
Contact: Jason(Manager)
Contact Me:

Tell:+86-19921425125 Mobile:+86-19921425125 Email:0615144241081040913855105@124qq3.1312co6m

 

FL SWITCH 3006T-2FX Industrial Ethernet Switch

2891036

Managed Ethernet switch with six RJ45 ports at 10/100 Mbps, two SC format fiber optic ports and an operating temperature of -40°C ... +75°C

Width 54.4 mm
Height 146.4 mm
Depth 125 mm

Utilization restriction
EMC note EMC: class A product, see manufacturer's declaration in the download area
Utilization restriction
CCCex note Use in potentially explosive areas is not permitted in China.

Housing material Aluminum

Mounting type DIN rail mounting

Ethernet (RJ45)
Connection method RJ45
Note on the connection method Auto negotiation and autocrossing
Transmission speed 10/100 Mbps
Transmission physics Ethernet in RJ45 twisted pair
Transmission length 100 m
No. of channels 6 (RJ45 ports)
Fiber optic interface
Connection method SC
Transmission speed 100 Mbps (full duplex)
Transmission physics multi-mode fiberglass
Transmission length 12.1 km (fiberglass with F-G 62.5/125 0.7 dB/km F1000)
3.3 km (fiberglass with F-G 62.5/125 2.6 dB/km F600)
7.1 km (fiberglass with F-G 50/125 0.7 dB/km F1200)
3.1 km (fiberglass with F-G 50/125 1.6 dB/km F800)
Wavelength 1300 nm
No. of channels 2 (SC multi-mode)

Product type Switch
Product family Managed Switch 3000
Type Block design
Insulation characteristics
Protection class III (VDE 0106, IEC 60536)
Switch functions
Basic functions Store and forward switch, Extended Ring and IEEE redundancy, Multicast control, IGMP snooping, trunking, Port and Tagging VLANs, Port and IEEE 802.1x security, SNMP V3 and Https security, SNTP, web customization, user accounts
Signal contact control voltage 24 V DC
Signal contact control current 100 mA
Redundancy ERR (Extended ring redundancy)
Status and diagnostic indicators LEDs: US1, US2 (redundant voltage supply), link and activity per port
Security functions
Basic functions Store and forward switch, Extended Ring and IEEE redundancy, Multicast control, IGMP snooping, trunking, Port and Tagging VLANs, Port and IEEE 802.1x security, SNMP V3 and Https security, SNTP, web customization, user accounts

Local diagnostics US1, US2 Supply voltage Green LED
LNK/ACT Link status/data transmission Green LED
100 Data transmission speed Red LED
Maximum power dissipation for nominal condition 7.92 W
Test section Supply voltage/functional ground 500 V 1 min.
Transmission medium Copper
Supply
Supply voltage (DC) 24 V DC (redundant)
Supply voltage range 12 V DC ... 48 V DC
Inrush current 4.6 A (3.1 ms)
Residual ripple 3.6 VPP (within the permitted voltage range)
Typical current consumption 287 mA (at US = 24 V DC)
Function
Signal contact control voltage 24 V DC
Signal contact control current 100 mA

Connection technology
Connection name Power supply
pluggable yes
Power supply
Connection method Screw connection
Conductor cross section, rigid 0.2 mm² ... 2.5 mm²
Conductor cross section, flexible 0.2 mm² ... 2.5 mm²
Conductor cross section AWG 24 ... 12
Stripping length 7 mm

Ambient conditions
Degree of protection IP20
Ambient temperature (operation) -40 °C ... 75 °C
Ambient temperature (storage/transport) -40 °C ... 85 °C
Permissible humidity (operation) 5 % ... 95 % (non-condensing)
Permissible humidity (storage/transport) 5 % ... 95 % (non-condensing)
Air pressure (operation) 57 kPa ... 108 kPa (up to 4850 m above mean sea level)
Air pressure (storage/transport) 57 kPa ... 108 kPa (up to 4850 m above mean sea level)

FL SWITCH 3006T-2FX - Industrial Ethernet Switch

Disclaimer:All information is provided by registered users. You may assess risks based on corresponding qualifications.