Email verifiedBusiness License verified

PLC-RSC- 24DC、1 MS ACT - Relay Module

2024-05-07T06:34:43Z 
Company: 上海当临自动化科技有限公司
Location: China - Shanghai,上海市青浦区练西公路2850号1幢
Price: Negotiation
Contact: Jason(Manager)
Contact Me:

Tell:+86-19921425125 Mobile:+86-19921425125 Email:101267132046556129069412@q9q97.c713om

 

PLC-RSC- 24DC/ 1/MS/ACT Relay Module

2909661

PLC-INTERFACE for output functions, consisting of PLC-BSC.../ACT basic terminal block with screw connection and plug-in miniature relay with power contact and manual operation, 1 N/O contact, 24 V DC input voltage

Product type Relay Module
Product family PLC-INTERFACE
Application Palm switch
Operating mode 100% operating factor
Mechanical service life 1x 107 cycles

Maximum power dissipation for nominal condition 0.22 W
Test voltage (Winding/contact) 4 kV AC (50 Hz, 1 min., winding/contact)
Insulation characteristics: Coil/contact
Rated insulation voltage 250 V
Rated impulse withstand voltage 6 kV
Overvoltage category III
Degree of pollution 3

Coil side
Nominal input voltage UN 24 V DC
Input voltage range 18.5 V DC ... 33.6 V DC (20 °C)
Drive and function monostable
Drive (polarity) polarized
Typical input current at UN 9 mA
Typical response time 5 ms
Typical release time 8 ms
Protective circuit Reverse polarity protection; Polarity protection diode
Freewheeling diode; Freewheeling diode
Operating voltage display Yellow LED

Switching
Contact switching type 1 N/O contact
Type of switch contact Single contact
Contact connection type Power contact
Contact material AgSnO
Maximum switching voltage 250 V AC/DC (The separating plate PLC-ATP should be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal blocks in adjacent modules. Potential bridging is then carried out with FBST 8-PLC... or ...FBST 500...)
Minimum switching voltage 5 V (at 100 mA)
Limiting continuous current 6 A
Maximum inrush current 10 A (4 s)
Min. switching current 10 mA (12 V)
Short-circuit current 200 A (conditional short-circuit current)
Interrupting rating (ohmic load) max. 140 W (at 24 V DC)
20 W (at 48 V DC)
18 W (at 60 V DC)
23 W (at 110 V DC)
40 W (at 220 V DC)
1500 VA (for 250 V AC)
Output fuse 4 A gL/gG NEOZED
Switching capacity 2 A (at 24 V, DC13)
0.2 A (at 110 V, DC13)
0.1 A (at 220 V, DC13)
3 A (at 24 V, AC15)
3 A (at 120 V, AC15)
3 A (at 230 V, AC15)

Connection method Screw connection
Stripping length 8 mm
Screw thread M3
Conductor cross section rigid 0.14 mm² ... 2.5 mm²
Conductor cross section flexible 0.14 mm² ... 2.5 mm²
0.2 mm² ... 2.5 mm² (Single ferrule)
2x 0.5 mm² ... 1.5 mm² (TWIN ferrule)
Conductor cross section AWG 26 ... 14
Tightening torque 0.6 Nm ... 0.8 Nm

Width 6.2 mm
Height 80 mm
Depth 94 mm

Color gray (RAL 7042)
Flammability rating according to UL 94 V0 (Housing)

Ambient conditions
Degree of protection (Relay) RT II (Relay)
Degree of protection (Relay base) IP20 (Relay base)
Ambient temperature (operation) -40 °C ... 60 °C
Ambient temperature (storage/transport) -40 °C ... 85 °C

CE
Certificate CE-compliant
UKCA
Certificate UKCA-compliant

PLC-RSC- 24DC、1 MS ACT - Relay Module

Disclaimer:All information is provided by registered users. You may assess risks based on corresponding qualifications.