Email verifiedBusiness License verified

PLC-OSC- 5DC 300DC、1 - Solid-state relay module

2024-05-09T03:15:43Z 
Company: 上海当临自动化科技有限公司
Location: China - Shanghai,上海市青浦区练西公路2850号1幢
Price: Negotiation
Contact: Jason(Manager)
Contact Me:

Tell:+86-19921425125 Mobile:+86-19921425125 Email:936772311654113216199@1q71q.13c12o8m

 

PLC-OSC- 5DC/300DC/ 1 Solid-state relay module

2980652

PLC-INTERFACE, integrated solid-state relay, with screw connection, for mounting on NS 35/7,5 DIN rails, input: 5 V DC, output: 12 - 300 V DC/1 A

Product type Solid-state relay module
Product family PLC-INTERFACE
Application With integrated solid-state relay
Operating mode 100% operating factor
Insulation characteristics
Insulation Basic insulation
Insulation characteristics: Standards/regulations
Insulation Basic insulation
Overvoltage category III
Pollution degree 2

Maximum power dissipation for nominal condition 0.08 W
Standards/regulations
Rated insulation voltage 300 V
Rated surge voltage 2.5 kV

Nominal input voltage UN 5 V DC
Input voltage range in reference to UN 0.8 ... 1.2
Input voltage range 4 V DC ... 6 V DC
Switching threshold "0" signal in reference to UN ≤ 0.4
Switching threshold "1" signal in reference to UN ≥ 0.8
Typical input current at UN 15 mA
Typical response time 0.8 ms
Typical turn-off time 1.5 ms
Operating voltage display Yellow LED
Protective circuit Reverse polarity protection; Polarity protection diode
Surge protection; Varistor
Transmission frequency 50 Hz

Designation Output data
Contact switching type 1 N/O contact
Design of digital output electronic
Output voltage range 12 V DC ... 300 V DC (Partition plate PLC-ATP must be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal points in adjacent modules. Potential bridging is then carried out with FBST 8-PLC... or ...FBST 500...)
Limiting continuous current 1 A (see derating curve)
Voltage drop at max. limiting continuous current < 500 mV
Protective circuit Reverse polarity protection; Polarity protection diode
Surge protection; Varistor

Connection method Screw connection
Stripping length 8 mm
Screw thread M3
Conductor cross section rigid 0.14 mm² ... 2.5 mm²
Conductor cross section flexible 0.14 mm² ... 2.5 mm²
0.2 mm² ... 2.5 mm² (Single ferrule)
2x 0.5 mm² ... 1.5 mm² (TWIN ferrule)
Conductor cross section AWG 26 ... 14
Tightening torque 0.45 Nm ... 0.55 Nm (Usually these terminal blocks must be supported during conductor connection (held by one hand, supported on the housing))

Width 6.2 mm
Height 80 mm
Depth 95 mm

Color gray (RAL 7042)
Flammability rating according to UL 94 V0 (Housing)

Ambient conditions
Ambient temperature (operation) -25 °C ... 60 °C
Ambient temperature (storage/transport) -40 °C ... 85 °C

CE
Certificate CE-compliant
UKCA
Certificate UKCA-compliant
Shipbuilding approval
Certificate TAE0000196
Corrosive gas test
Identification ISA-S71.04. G3 Harsh Group
EN 60068-2-60
DNV GL data
Temperature D
Humidity A
Vibration B/C
EMC B
Enclosure Required protection according to the Rules shall be provided upon installation on board

PLC-OSC- 5DC 300DC、1 - Solid-state relay module

Disclaimer:All information is provided by registered users. You may assess risks based on corresponding qualifications.