TRIO-PS-2G/1AC/24DC/5/B+D Power supply unit

2903144

Primary-switched TRIO POWER power supply with push-in connection for DIN rail mounting, input: 1-phase, output: 24 V DC/5 A

TRIO POWER power supplies for more stringent EMC requirements in shipbuilding
The TRIO POWER power supply range with Push-in connection has been perfected for use in shipbuilding. All functions and the space-saving design of the single and three-phase modules are optimally tailored to the stringent requirements. Under challenging ambient conditions, the power supply units, which feature an extremely robust electrical and mechanical design, ensure the reliable supply of all loads.

AC operation
Network type Star network
Nominal input voltage range 100 V AC ... 240 V AC
Input voltage range 100 V AC ... 240 V AC -15 % ... +10 %
Derating < 100 V AC (1 %/V)
Input voltage range AC 85 V AC ... 264 V AC
Switch-on voltage >
Electric strength, max. ≤ 300 V AC 15 s
Typical national grid voltage 120 V AC
230 V AC
Voltage type of supply voltage AC/DC
Inrush current ≤ 16 A (typical)
Inrush current integral (I2t) < 0.6 A2s
Inrush current limitation typ. 16 A (after 1 ms)
AC frequency range 50 Hz ... 60 Hz ±5 Hz
Frequency range (fN) 50 Hz ... 60 Hz ±10 %
Mains buffering time typ. 20 ms (120 V AC)
typ. 100 ms (230 V AC)
Current consumption 2.2 A (100 V AC)
1.9 A (120 V AC)
1.1 A (230 V AC)
1.1 A (240 V AC)
Nominal power consumption 272 VA
Protective circuit Transient surge protection; Varistor
Power factor (cos phi) 0.5
Typical response time < 1 s
Input fuse 6.3 A (internal (device protection))
Recommended breaker for input protection 6 A ... 16 A (Characteristics B, C, D, K)
Discharge current to PE < 0.25 mA
DC operation
Nominal input voltage range 110 V DC ... 250 V DC
Input voltage range 99 V DC ... 275 V DC
Derating < 110 V DC (1 %/V)
Switch-on voltage ≥ 85 V DC
Shut-down voltage < 60 V DC
Voltage type of supply voltage AC/DC
Mains buffering time > 100 ms (230 V AC)
Current consumption 1.4 A (110 V DC)
0.6 A (250 V DC)

Efficiency > 89 % (for 230 V AC and nominal values)
Output characteristic U/I with dynamic load reserve
Nominal output voltage 24 V DC ±1 %
Setting range of the output voltage (USet) 24 V DC ... 28 V DC (> 24 V DC, constant capacity restricted)
Nominal output current (IN) 5 A
Dynamic Boost (IDyn.Boost) 7.5 A (5 s)
Derating > 60 °C ... 70 °C (2.5 %/K)
Feedback voltage resistance ≤ 35 V DC
Protection against overvoltage at the output (OVP) ≤ 30 V DC
Control deviation < 1 % (change in load, static 10 % ... 90 %)
< 3 % (Dynamic load change 10 % ... 90 %, 10 Hz)
< 0.1 % (change in input voltage ±10 %)
Residual ripple < 50 mVPP (with nominal values)
Output power 120 W
180 W
Maximum no-load power dissipation < 1 W
Power loss nominal load max. < 16 W
Rise time ≤ 12 ms (UOUT (10 % ... 90 %))
Connection in parallel yes, for redundancy and increased capacity
Connection in series yes
Signal: DC OK
Maximum switching voltage 30 V AC/DC
Continuous load current 100 mA

TRIO-PS-2G 1AC 24DC 5 B+D - Power supply unit

Disclaimer:All information is provided by registered users. You may assess risks based on corresponding qualifications.

  • PSR-PC20-1NO-1NC-24DC-SP - Coupling relayPSR-PC20-1NO-1NC-24DC-SP - Coupling relay
    PSR-PC20-1NO-1NC-24DC-SP - Coupling relay 2700578 Coupling relay for SIL 3 high - and low-demand applications , couples digital output signals to the" "
  • PSR-MC72-2NO-1DO-24DC-SC - Safety relaysPSR-MC72-2NO-1DO-24DC-SC - Safety relays
    PSR-MC72-2NO-1DO-24DC-SC - Safety relays 2702096 Safety relay for emergency stop , safety doors , light grid up to SIL 3 , Cat ." "
  • PSR-MC72-2NO-1DO-24DC-SP - Safety relaysPSR-MC72-2NO-1DO-24DC-SP - Safety relays
    PSR-MC72-2NO-1DO-24DC-SP - Safety relays 2702097 Safety relay for emergency stop , safety doors , light grid up to SIL 3 , Cat ." "
  • PSI-MOS-PROFIB FO1300 E - FO convertersPSI-MOS-PROFIB FO1300 E - FO converters
    PSI-MOS-PROFIB/FO1300 E - FO converters 2708559 Fiber optic converter with integrated optical diagnostics , alarm contact , for PROFIBUS up to 12 Mbps ," "