ELR W3-230AC 500AC- 2I - Hybrid motor starter
ELR W3-230AC/500AC- 2I - Hybrid motor starter
2297044
"4 in 1" three-phase semiconductor reversing contactor with 230 V AC input, 2 A output current, emergency stop function, and adjustable overload shutdown.
Product type Hybrid motor starters
Product family CONTACTRON
Operating mode 100% operating factor
Number of phases 3
Motor starter type Reversing starter
Maximum power dissipation for nominal condition 2.2 W
Switching frequency ≤ 2 Hz (Load-dependent)
Maximum power dissipation 4.7 W
Minimum power dissipation 2.6 W
Supply
Rated control circuit supply voltage US 230 V AC
Control supply voltage range 92 V AC ... 253 V AC
Rated control supply current IS 4 mA
Mains frequency 40/100 Hz
Protective circuit Surge protection
Insulation characteristics
Rated insulation voltage 500 V
Rated surge voltage 6 kV
Overvoltage category III
Degree of pollution 2
Insulation characteristics between the control input and control supply voltage, and auxiliary circuit to the main circuit Safe isolation (IEC 60947-1) at operating voltage ≤ 300 V AC
Basic insulation (IEC 60947-1) at operating voltage 300 V AC ... 500 V AC
Isolation characteristics between the control input and control supply voltage to auxiliary circuit Safe isolation (IEC 60947-1) in the auxiliary circuit ≤ 300 V AC
Control
Input name Control input right/left
Rated actuating voltage UC 230 V AC
Triggering voltage range 92 V AC ... 253 V AC
Rated actuating current IC 7 mA
Switching threshold 44 V AC (“0” signal)
85 V AC (“1” signal)
Switching level < 5 V DC (For EMERGENCY STOP)
Typical response time < 35 ms
Typical turn-off time < 80 ms
AC output
Rated operating voltage Ue 500 V AC
Operating voltage range 42 V AC ... 550 V AC
Rated operating current Ie 2.4 A (AC-51)
2.4 A (AC-53a)
Mains frequency 50/60 Hz
Load current range 180 mA ... 2.4 A (see to derating)
Trigger characteristic in acc. with IEC 60947-4-2 Class 10A
Cooling time 20 min. (for auto reset)
Leakage current 0 mA
Residual voltage < 0.3 V
Surge current 100 A (t = 10 ms)
Protective circuit Surge protection
Acknowledge output
Note Confirmation: floating change-over contact, signal contact
Contact switching type 1 changeover contact
Switching capacity in accordance with IEC 60947-5-1 3 A (230 V, AC15)
2 A (24 V, DC13)
Residual voltage < 0.5 V
Control circuits
Connection method Screw connection
Stripping length 8 mm
Screw thread M3
Conductor cross section rigid 0.2 mm² ... 2.5 mm²
Conductor cross section flexible 0.2 mm² ... 2.5 mm²
Conductor cross section AWG 24 ... 14
Tightening torque 0.5 Nm ... 0.6 Nm
5 lbf-in. ... 7 lbf-in.
Load circuit
Connection method Screw connection
Stripping length 8 mm
Screw thread M3
Conductor cross section rigid 0.2 mm² ... 2.5 mm²
Conductor cross section flexible 0.2 mm² ... 2.5 mm²
Conductor cross section AWG 24 ... 14
Tightening torque 0.5 Nm ... 0.6 Nm
5 lbf-in. ... 7 lbf-in.
Status display Yellow LED
Operating voltage display Green LED
Error indication Red LED
Width 22.5 mm
Height 107 mm
Depth 114 mm
Flammability rating according to UL 94 V0 (Housing)
Disclaimer:All information is provided by registered users. You may assess risks based on corresponding qualifications.
- PSR-PC20-1NO-1NC-24DC-SP - Coupling relayPSR-PC20-1NO-1NC-24DC-SP - Coupling relay 2700578 Coupling relay for SIL 3 high - and low-demand applications , couples digital output signals to the" "
- PSR-MC72-2NO-1DO-24DC-SC - Safety relaysPSR-MC72-2NO-1DO-24DC-SC - Safety relays 2702096 Safety relay for emergency stop , safety doors , light grid up to SIL 3 , Cat ." "
- PSR-MC72-2NO-1DO-24DC-SP - Safety relaysPSR-MC72-2NO-1DO-24DC-SP - Safety relays 2702097 Safety relay for emergency stop , safety doors , light grid up to SIL 3 , Cat ." "
- PSI-MOS-PROFIB FO1300 E - FO convertersPSI-MOS-PROFIB/FO1300 E - FO converters 2708559 Fiber optic converter with integrated optical diagnostics , alarm contact , for PROFIBUS up to 12 Mbps ," "