Email verifiedBusiness License verified

SACC-M12MRB-3PL SH PB - Data connector

2024-05-08T07:32:29Z 
Company: 上海当临自动化科技有限公司
Location: China - Shanghai,上海市青浦区练西公路2850号1幢
Price: Negotiation
Contact: Jason(Manager)
Contact Me:

Tell:+86-19921425125 Mobile:+86-19921425125 Email:3116701026155712106696@1113qq124.c2o3m

 

SACC-M12MRB-3PL SH PB Data connector

1424697

Data connector, PROFIBUS DP (12 Mbps), 3-position, shielded, Plug angled M12, coding: B, Push-lock spring connection, knurl material: Zinc die-cast, nickel-plated, external cable diameter 4 mm ... 8 mm

Assembly instruction: NOTE: Observe the permissible bending radii when laying conductors, since the degree of protection may be put in jeopardy if the bending forces are too high. Alleviate mechanical loads upstream of the connector, e.g. by using cable ties.

Assembly instructions The connector pin assignment can be rotated 45° to the cable outlet
The wires can be connected both with ferrules and without ferrules

Product type Circular connector (cable-side)
Application Data
Sensor type PROFIBUS DP
Number of positions 3
No. of cable outlets 1
Shielded yes
Coding B
Cable outlet angled
Insulation characteristics
Overvoltage category II
Degree of pollution 3

Dimensional drawing
Length 50 mm
External dimensions
Outside diameter 4 mm ... 8 mm
Housing
Diameter housing 19 mm

Material TPE-U
PA 6
Flammability rating according to UL 94 V0
Seal material NBR
Material of grip body Zinc die-cast, nickel-plated
Contact material CuSn
Contact surface material Ni/Au
Contact carrier material PA 6.6
Material for screw connection Zinc die-cast, nickel-plated
Standards/regulations PA 6.6: Fire protection in rail vehicles - requirement sets R22, R23, R24, R25, and R26 acc. to DIN EN 45545-2 (Risk level HL1 - HL3)
PA 6: Fire protection in rail vehicles - requirement sets R22, R23, and R24 acc. to DIN EN 45545-2 (Risk level HL1 - HL3)

Conductor connection
Connection method Push-lock spring connection
Connection cross section 0.14 mm² ... 0.75 mm² (without ferrule)
0.08 mm² ... 0.5 mm² (with ferrule)
0.14 mm² ... 0.75 mm² (solid)
Connection cross section AWG 26 ... 18 (without ferrule)
28 ... 20 (with ferrule)
Stripping length of the individual wire 7 mm
Tightening torque 0.4 Nm (M12 knurl)
0.8 Nm (Connector with coupling sleeve)
3 Nm (Pressure nut with coupling sleeve)
Pin assignment
Contact | Color (signal designation) | Contact (optional) 2 = GN (A)
4 = RD (B)
5 = GY

Rated surge voltage 1.5 kV
Contact resistance ≤ 5 mΩ
Insulation resistance ≥ 100 MΩ
Nominal voltage UN 48 V AC
60 V DC
Nominal current IN 4 A (2 A when using 0.14 mm² conductors)

Mechanical data
Insertion/withdrawal cycles ≥ 100

Connection 1
Head design Plug
Head cable outlet angled
Head thread type M12
Coding B

Signal type/category PROFIBUS DP, 12 Mbps
Stripping length of the individual wire 7 mm

SACC-M12MRB-3PL SH PB - Data connector

Disclaimer:All information is provided by registered users. You may assess risks based on corresponding qualifications.

  • ELR H5-IES-PT-24DC 500AC-06-T - Hybrid motor starterELR H5-IES-PT-24DC 500AC-06-T - Hybrid motor starter
    ELR H5-IES-PT-24DC/500AC-06-T - Hybrid motor starter 2906058 Hybrid motor starter ; functions : Start motor , Reverse motor , Motor protection , Emergency" "
  • RAD-SPL-2-N/N - Antenna splitterRAD-SPL-2-N/N - Antenna splitter
    RAD-SPL-2-N/N - Antenna splitter 2702293 Antenna splitter , frequency range : 0.3 GHz ... 6 GHz , degree of protection : IP65 , connection : 3 x N ( female" "
  • PTFIX 6 6X2,5-NS35A RD - Distribution blockPTFIX 6 6X2,5-NS35A RD - Distribution block
    PTFIX 6/6X2,5-NS35A RD - Distribution block 3273202 Distribution block , Block with horizontal alignment and integrated supply , nom ." "
  • PTFIX 6 6X2,5-NS35A BU - Distribution blockPTFIX 6 6X2,5-NS35A BU - Distribution block
    PTFIX 6/6X2,5-NS35A BU - Distribution block 3273200 Distribution block , Block with horizontal alignment and integrated supply , nom ." "