DT-UFB-IB-RBI Surge protection device

2800055

Attachment plug with surge protection for 5-conductor remote bus input. Connection: 9-pos. D-SUB plug - socket. Can alternatively be snapped onto DIN rails. Incl. 1 m cable with 9-pos. D-SUB connection.


Product type Surge protection for information technology
Product family DATATRAB
IEC test classification B2
C1
C2
C3
D1
VDE requirement class B2
C1
C2
C3
D1
Type Attachment plug for DIN rail mounting
Number of positions 5
Wire pairs per module 2
Insulation characteristics
Overvoltage category II

Connection method D-SUB-9

Dimensional drawing
Width 25 mm
Height 110 mm
Depth 63 mm

Color Silver
black (RAL 9005)
Housing material Zinc die-cast

Mechanical data
Open side panel No

Direction of action Line-Line & Line-Ground/Shield
Maximum continuous voltage UC 5.8 V DC
Rated current ≤ 180 mA (25 °C)
Operating effective current IC at UC ≤ 1 µA
Residual current IPE ≤ 5 µA
Nominal discharge current In (8/20) µs (line-line) ≤ 5 kA
Nominal discharge current In (8/20) µs (line-ground) ≤ 5 kA
Total discharge current Itotal (8/20) µs 10 kA
Output voltage limitation at 1 kV/µs (line-earth) spike ≤ 700 V
Output voltage limitation at 1 kV/µs (line-line) static ≤ 15 V
Output voltage limitation at 1 kV/µs (line-earth) static ≤ 700 V
Output voltage limitation at 1 kV/µs (line-signalground) static ≤ 15 V
Residual voltage at In (conductor-conductor) ≤ 25 V
Residual voltage at In (conductor-ground) ≤ 55 V
Residual voltage at In (line-signalground) ≤ 25 V
Voltage protection level Up (line-line) ≤ 16 V (B2 - 100 A)
≤ 20 V (C1 - 500 A)
≤ 20 V (C2 - 1 kA)
≤ 60 V (C2 - 5 kA)
Voltage protection level Up (line-earth) ≤ 700 V (B2 - 100 A)
≤ 700 V (C1 - 500 A)
≤ 700 V (C2 - 5 kA)
Response time tA (line-line) ≤ 1 ns
Response time tA (line-earth) ≤ 100 ns
Input attenuation aE, sym. typ. 0.5 dB (≤ 5 MHz / 150 Ω)
typ. 0.6 dB (≤ 10 MHz / 100/150 Ω)
Cut-off frequency fg (3 dB), sym. in 100 Ω system ≥ 100 MHz
Cut-off frequency fg (3 dB), sym. in 150 Ω system ≥ 100 MHz
Capacity (Core-Core) typ. 20 pF
Resistance per path typ. 7 Ω
Surge protection fault message none
Impulse durability (line-line) C1 - 1 kV / 500 A
C2 - 10 kV / 5 kA
B2 - 4 kV / 100 A
Impulse durability (line-earth) B2 - 4 kV / 100 A
C1 - 1 kV / 500 A
C2 - 10 kV / 5 kA
D1 - 1 kA

Ambient conditions
Degree of protection IP20
Ambient temperature (operation) -40 °C ... 85 °C

VDE requirement class B2
C1
C2
C3
D1

DT-UFB-IB-RBI - Surge protection device

Disclaimer:All information is provided by registered users. You may assess risks based on corresponding qualifications.

  • PSR-PC20-1NO-1NC-24DC-SP - Coupling relayPSR-PC20-1NO-1NC-24DC-SP - Coupling relay
    PSR-PC20-1NO-1NC-24DC-SP - Coupling relay 2700578 Coupling relay for SIL 3 high - and low-demand applications , couples digital output signals to the" "
  • PSR-MC72-2NO-1DO-24DC-SC - Safety relaysPSR-MC72-2NO-1DO-24DC-SC - Safety relays
    PSR-MC72-2NO-1DO-24DC-SC - Safety relays 2702096 Safety relay for emergency stop , safety doors , light grid up to SIL 3 , Cat ." "
  • PSR-MC72-2NO-1DO-24DC-SP - Safety relaysPSR-MC72-2NO-1DO-24DC-SP - Safety relays
    PSR-MC72-2NO-1DO-24DC-SP - Safety relays 2702097 Safety relay for emergency stop , safety doors , light grid up to SIL 3 , Cat ." "
  • PSI-MOS-PROFIB FO1300 E - FO convertersPSI-MOS-PROFIB FO1300 E - FO converters
    PSI-MOS-PROFIB/FO1300 E - FO converters 2708559 Fiber optic converter with integrated optical diagnostics , alarm contact , for PROFIBUS up to 12 Mbps ," "