Email verifiedBusiness License verified

PT 2+1-S-48DC FM - Type 3 surge protection device

2024-05-08T03:41:35Z 
Company: 上海当临自动化科技有限公司
Location: China - Shanghai,上海市青浦区练西公路2850号1幢
Price: Negotiation
Contact: Jason(Manager)
Contact Me:

Tell:+86-19921425125 Mobile:+86-19921425125 Email:56271122610592121160913@13q24q.11c9o6m

 

PT 2+1-S-48DC/FM Type 3 surge protection device

2817958

Rail-mountable surge arrester as device protection for terminal equipment, fault signal in the plug and signaling contact in the base element, 2-section, pluggable. Design: 48 V DC

Product type Device protection
IEC power supply system DC
Type DIN rail module, two-section, divisible
Surge protection fault message Optical, remote indicator contact
Insulation characteristics
Overvoltage category III
Pollution degree 2
Arrester can be tested with CHECKMASTER from software version: From SW rev. 1.00
IEC test classification III
T3
EN type T3
Number of ports One

Indicator/remote signaling
Connection name Remote fault indicator contact
Switching function N/C contact
Operating voltage 7 V DC ... 70 V DC (open collector)
Operating current 5 mA DC ... 15 mA (open collector)

Connection method Screw connection
Screw thread M3
Tightening torque 0.8 Nm
Conductor cross section flexible 0.2 mm² ... 2.5 mm²
Conductor cross section rigid 0.2 mm² ... 4 mm²
Conductor cross section AWG 24 ... 12

Dimensional drawing
Width 17.7 mm
Height 90 mm
Depth 65.5 mm (incl. DIN rail 7.5 mm)
Horizontal pitch 1 Div.

Color black (RAL 9005)
Copper
Flammability rating according to UL 94 V-0
CTI value of material 600
Insulating material PA 6.6
Housing material PA 6.6

Mode of protection L-N
L-PE
N-PE
(L+) - (L-)
(L+/L-) - PE
Direction of action 1L-N & N-PE
Nominal voltage UN 48 V DC
Maximum continuous voltage UC 60 V DC
Rated load current IL 26 A (30 °C)
Residual current IPE ≤ 10 µA
Nominal discharge current In (8/20) µs 500 A
Combination wave UOC 1 kV (2 Ω)
1 kV (2 Ω)
Voltage protection level Up ≤ 120 V
Response time tA (L-N) ≤ 1 ns
Response time tA (L-PE) ≤ 1 ns
Short-circuit current rating ISCCR 200 A (without backup fuse for UC)
Max. backup fuse with branch wiring 50 A (gG)

Ambient conditions
Degree of protection IP20
Ambient temperature (operation) -40 °C ... 80 °C
Ambient temperature (storage/transport) -40 °C ... 80 °C
Altitude ≤ 2000 m (amsl)
Permissible humidity (operation) 5 % ... 95 %

Air clearances and creepage distances
Standards/regulations DIN VDE 0110-1 / IEC 60664-1 / DIN VDE 0675-6 / IEC 61643-1
Standards/specifications EN 61643-11
Note 2012
Standards/specifications IEC 61643-11
Note 2011

Mounting type DIN rail: 35 mm

PT 2+1-S-48DC FM - Type 3 surge protection device

Disclaimer:All information is provided by registered users. You may assess risks based on corresponding qualifications.

  • TTC-6-3-HF-F-M-12DC-UT-I - Surge protection deviceTTC-6-3-HF-F-M-12DC-UT-I - Surge protection device
    TTC-6-3-HF-F-M-12DC-UT-I - Surge protection device 2906769 Surge protection with integrated status indicator and knife disconnection for three signal wires" "
  • IB IL AI 2 SF-230-PAC - Analog moduleIB IL AI 2 SF-230-PAC - Analog module
    IB IL AI 2/SF-230-PAC - Analog module 2861577 Inline , Analog input terminal , Analog inputs : 2 , 0 V ... 10 V , -10 V ... 10 V , 0 mA ... 20 mA , 4 mA" "
  • P-FU 5X20 LED 24-5 - Fuse plugP-FU 5X20 LED 24-5 - Fuse plug
    P-FU 5X20 LED 24-5 - Fuse plug 3209248 Fuse plug , Suitable for terminal blocks with a width of 5.2 mm and above with TG zone , nom ." "
  • SACC-M12MR-5PL M - ConnectorSACC-M12MR-5PL M - Connector
    SACC-M12MR-5PL M - Connector 1424651 Connector , Universal , 5-position , unshielded , Plug angled M12 , coding : A , Push-lock spring connection , knurl" "