Company: | 上海当临自动化科技有限公司 |
Location: | China - Shanghai,上海市青浦区练西公路2850号1幢 |
Price: | Negotiation |
Contact: | Jason(Manager) |
Contact Me: |
Tell:+86-19921425125 Mobile:+86-19921425125 Email:7715541243812499787513502@q612q.6c107om |
USLKG 3 N - Ground terminal
USLKG 3 N - Ground terminal
3000611
Ground terminal, number of connections: 2, number of positions: 1, connection method: Screw connection, cross section: 0.2 mm2 - 4 mm2, mounting: PE foot with mounting screw, M2.5, mounting type: NS 35/7,5, NS 35/15, NS 32, color: green-yellow
Product type Ground terminal block
Number of positions 1
Number of connections 2
Number of rows 1
Insulation characteristics
Overvoltage category III
Degree of pollution 3
Rated surge voltage 8 kV
Maximum power dissipation for nominal condition 0.77 W
Grounding foot Yes
Number of connections per level 2
Nominal cross section 2.5 mm²
Level 1 above 1 below 1
Screw thread M3
Note Please observe the current carrying capacity of the DIN rails.
Tightening torque 0.6 ... 0.8 Nm
Stripping length 7 mm
Connection in acc. with standard IEC 60947-7-2
Conductor cross section rigid 0.2 mm² ... 4 mm²
Cross section AWG 24 ... 12 (converted acc. to IEC)
Conductor cross section flexible 0.2 mm² ... 2.5 mm²
Conductor cross section, flexible [AWG] 24 ... 14 (converted acc. to IEC)
Conductor cross-section flexible (ferrule without plastic sleeve) 0.25 mm² ... 2.5 mm²
Flexible conductor cross section (ferrule with plastic sleeve) 0.2 mm² ... 2.5 mm²
Width 5.2 mm
End cover width 1.5 mm
Height 42.5 mm
Depth on NS 32 55.2 mm
Depth on NS 35/7,5 50.2 mm
Depth on NS 35/15 57.7 mm
Color green-yellow
Flammability rating according to UL 94 V0
Insulating material group I
Insulating material PA
Static insulating material application in cold -60 °C
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) 130 °C
Relative insulation material temperature index (Elec., UL 746 B) 130 °C
Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26 HL 1 - HL 3
Calorimetric heat release NFPA 130 (ASTM E 1354) 28 MJ/kg
Surface flammability NFPA 130 (ASTM E 162) passed
Specific optical density of smoke NFPA 130 (ASTM E 662) passed
Smoke gas toxicity NFPA 130 (SMP 800C) passed
General
Terminal block mounting 0.5 Nm ... 0.6 Nm (PE foot with mounting screw, M2.5)
Mechanical data
Open side panel No
Ambient conditions
Ambient temperature (operation) -60 °C ... 110 °C (Operating temperature range incl. self-heating; for max. short-term operating temperature, see RTI Elec.)
Ambient temperature (storage/transport) -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
Ambient temperature (assembly) -5 °C ... 70 °C
Ambient temperature (actuation) -5 °C ... 70 °C
Permissible humidity (operation) 20 % ... 90 %
Permissible humidity (storage/transport) 30 % ... 70 %
Connection in acc. with standard IEC 60947-7-2
Mounting type NS 35/7,5
NS 35/15
NS 32
Terminal block mounting 0.5 Nm ... 0.6 Nm (PE foot with mounting screw, M2.5)
Disclaimer:All information is provided by registered users. You may assess risks based on corresponding qualifications.
- Crane weighing scale for heavy loads equipmentMultiple Units : These scales can display weight measurements in various units , such as kilograms , pounds , ounces , or newtons , depending on the scale" "
- 833140N Digital Hang LED Scale Hanging Crane ScaleDigital Display : Most crane scales are equipped with a digital display that provides real-time weight readings ." "
- Rhorawill Crane Scale 300kgs Double Accuracy ElectronicCrane weighing scales , also known as crane scales or crane load cells , are specialized weighing devices designed for the purpose of lifting and weighing" "
- OCS-T-300kg Digital Hanging ScaleLCD digital crane mini hanging scale for commercial use The mini hanging scale features a die-cast aluminum casing for added strength ." "