P-FU 5X20 LED 24-5 - Fuse plug

2024-05-20T07:06:33Z 
Company: 上海当临自动化科技有限公司
Location: China - Shanghai,上海市青浦区练西公路2850号1幢
Price: Negotiation
Contact: Jason(Manager)
Contact Me:

Tell:+86-19921425125 Mobile:+86-19921425125 Email:9115441241413843498115565@10q1q7.23co7m

 

P-FU 5X20 LED 24-5 Fuse plug

3209248

Fuse plug, Suitable for terminal blocks with a width of 5.2 mm and above with TG zone, nom. voltage: 24 V, nominal current: 6.3 A, connection method: Plug-in connection, fuse type: G / 5 x 20, mounting type: Plug-in mounting, color: black

General Suitable for terminal blocks with a width of 5.2 mm and above with TG zone
Notes on operation Prior to replacing the cartridge fuse, disconnect the fuse connector from the basic terminal block.

Product type Fuse
Pitch 5.2 mm
Potentials 1
Insulation characteristics
Degree of pollution 3

Fuse G / 5 x 20
LED voltage range 12 V AC/DC ... 30 V AC/DC
LED current range 0.35 mA ... 0.95 mA

LED voltage range 12 V AC/DC ... 30 V AC/DC

Nominal current 6.3 A (the current is determined by the fuse used)
Maximum load current 6.3 A (the current is determined by the fuse used)
Nominal voltage 24 V (The current is determined by the fuse used, the voltage by the fuse or selected LED display.)

Width 6.2 mm
Height 25 mm
Depth 57.7 mm
Length 25 mm
Pitch 5.2 mm

Color black
Flammability rating according to UL 94 V0
Insulating material PA
Static insulating material application in cold -60 °C
Relative insulation material temperature index (Elec., UL 746 B) 130 °C
Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26 HL 1 - HL 3
Surface flammability NFPA 130 (ASTM E 162) passed
Specific optical density of smoke NFPA 130 (ASTM E 662) passed
Smoke gas toxicity NFPA 130 (SMP 800C) passed

Ambient conditions
Ambient temperature (operation) -60 °C ... 105 °C (max. short-term operating temperature RTI Elec.)
Ambient temperature (storage/transport) -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
Ambient temperature (assembly) -5 °C ... 70 °C
Ambient temperature (actuation) -5 °C ... 70 °C
Permissible humidity (storage/transport) 30 % ... 70 %

Mounting type Plug-in mounting