Email verifiedBusiness License verified

FL IF 2TX VS-RJ-F - Media module

2024-05-08T06:57:32Z 
Company: 上海当临自动化科技有限公司
Location: China - Shanghai,上海市青浦区练西公路2850号1幢
Price: Negotiation
Contact: Jason(Manager)
Contact Me:

Tell:+86-19921425125 Mobile:+86-19921425125 Email:36370210065127121361910@06qq3.124co13m

 

FL IF 2TX VS-RJ-F Media module

2832344

Interface module for connecting twisted pair cable, RJ45, connection direction forward


Utilization restriction
EMC note EMC: class A product, see manufacturer's declaration in the download area

Product type Extension module
Type Stand-Alone

Functionality
Basic functions Media module for modular managed switch

Maximum power dissipation for nominal condition 21.6 W
Transmission medium Copper
Supply
Supply voltage via head station
Power supply connection From FL SWITCH GHS or FXT
Typical current consumption 10 mA

Ethernet
Connection method RJ45
Transmission speed 10/100 Mbps (connection direction forwards)
Transmission physics Ethernet in RJ45 twisted pair
Transmission length 100 m (per segment)
No. of channels 2 (RJ45 ports)
Transmission speed 10/100 Mbps (connection direction forwards)
Transmission length 100 m (per segment)

Dimensional drawing
Width 31 mm
Height 75.7 mm
Depth 75.5 mm

Color green
Flammability rating according to UL 94 V0
Housing material PA 6.6

Ambient conditions
Degree of protection IP20
Ambient temperature (operation) -20 °C ... 55 °C (non-condensing)
Ambient temperature (storage/transport) -20 °C ... 80 °C
Permissible humidity (operation) 10 % ... 95 % (non-condensing)
Permissible humidity (storage/transport) 10 % ... 95 % (non-condensing)
Vibration (operation) in acc. with IEC 60068-2-6: 5g, 150 Hz

Conformance with EMC directives IEC 61000-6-2 IEC 61000-4-2 (ESD) Criterion B
IEC 61000-4-3 (immunity to radiated interference) Criterion A
IEC 61000-4-4 (burst) Criterion A
IEC 61000-4-5 (surge) Criterion A
IEC 61000-4-6 (immunity to conducted interference) Criterion A
IEC 61000-4-8 (immunity to magnetic fields) Criterion A
EN 55022 (emitted interference) Criterion A
Noise immunity EN 61000-6-2:2005
Electromagnetic compatibility Conformance with EMC Directive 2004/108/EC
Noise emission EN 61000-6-3/-4

Free from substances that could impair the application of coating In acc. with VW specification

Mounting type In the host system

FL IF 2TX VS-RJ-F - Media module

Disclaimer:All information is provided by registered users. You may assess risks based on corresponding qualifications.

  • TTC-6-3-HF-F-M-12DC-UT-I - Surge protection deviceTTC-6-3-HF-F-M-12DC-UT-I - Surge protection device
    TTC-6-3-HF-F-M-12DC-UT-I - Surge protection device 2906769 Surge protection with integrated status indicator and knife disconnection for three signal wires" "
  • IB IL AI 2 SF-230-PAC - Analog moduleIB IL AI 2 SF-230-PAC - Analog module
    IB IL AI 2/SF-230-PAC - Analog module 2861577 Inline , Analog input terminal , Analog inputs : 2 , 0 V ... 10 V , -10 V ... 10 V , 0 mA ... 20 mA , 4 mA" "
  • P-FU 5X20 LED 24-5 - Fuse plugP-FU 5X20 LED 24-5 - Fuse plug
    P-FU 5X20 LED 24-5 - Fuse plug 3209248 Fuse plug , Suitable for terminal blocks with a width of 5.2 mm and above with TG zone , nom ." "
  • SACC-M12MR-5PL M - ConnectorSACC-M12MR-5PL M - Connector
    SACC-M12MR-5PL M - Connector 1424651 Connector , Universal , 5-position , unshielded , Plug angled M12 , coding : A , Push-lock spring connection , knurl" "