Email verifiedBusiness License verified

SACC-M12MS-5PL M - Connector

2024-05-08T07:01:17Z 
Company: 上海当临自动化科技有限公司
Location: China - Shanghai,上海市青浦区练西公路2850号1幢
Price: Negotiation
Contact: Jason(Manager)
Contact Me:

Tell:+86-19921425125 Mobile:+86-19921425125 Email:1006711526951215220691213@q65q.12c9o4m

 

SACC-M12MS-5PL M Connector

1424649

Connector, Universal, 5-position, unshielded, Plug straight M12, coding: A, Push-lock spring connection, knurl material: Zinc die-cast, nickel-plated, external cable diameter 4 mm ... 8 mm

mbly instruction: NOTE: Observe the permissible bending radii when laying conductors, since the degree of protection may be put in jeopardy if the bending forces are too high. Alleviate mechanical loads upstream of the connector, e.g. by using cable ties.

Assembly instructions The wires can be connected both with ferrules and without ferrules

Product type Circular connector (cable-side)
Sensor type Universal
Number of positions 5
No. of cable outlets 1
Shielded no
Coding A
Cable outlet straight
Insulation characteristics
Overvoltage category II
Degree of pollution 3

Dimensional drawing
Length 60 mm
External dimensions
Outside diameter 4 mm ... 8 mm
Housing
Diameter housing 19 mm

Material PBT
PA 6
Flammability rating according to UL 94 V0
Seal material NBR
Material of grip body PA 6.6
Contact material CuSn
Contact surface material Ni/Au
Contact carrier material PA 6.6
Material for screw connection Zinc die-cast, nickel-plated
Standards/regulations PA 6.6: Fire protection in rail vehicles - requirement sets R22, R23, R24, and R26 acc. to DIN EN 45545-2 (Risk level HL1 - HL3)
PA 6: Fire protection in rail vehicles - requirement sets R22, R23, and R24 acc. to DIN EN 45545-2 (Risk level HL1 - HL3)
PBT: Fire protection in rail vehicles - requirement sets R22, R23, R24, and R26 acc. to DIN EN 45545-2 (Risk level HL1 - HL2, R26: HL3)

Conductor connection
Connection method Push-lock spring connection
Connection cross section 0.14 mm² ... 0.75 mm² (without ferrule)
0.08 mm² ... 0.5 mm² (with ferrule)
0.14 mm² ... 0.75 mm² (solid)
Connection cross section AWG 26 ... 18 (without ferrule)
28 ... 20 (with ferrule)
Stripping length of the individual wire 7 mm
Tightening torque 0.4 Nm (M12 knurl)
0.4 Nm (Connector with coupling sleeve)
1.5 Nm (Pressure nut with coupling sleeve)
Pin assignment
Contact | Color (signal designation) | Contact (optional) 1 = BN
2 = WH
3 = BU
4 = BK
5 = GY

Rated surge voltage 1.5 kV
Contact resistance ≤ 5 mΩ
Insulation resistance ≥ 100 MΩ
Nominal voltage UN 48 V AC
60 V DC
Nominal current IN 4 A (2 A when using 0.14 mm² conductors)

Mechanical data
Insertion/withdrawal cycles ≥ 100

Connection 1
Head design Plug
Head cable outlet straight
Head thread type M12
Coding A

SACC-M12MS-5PL M - Connector

Disclaimer:All information is provided by registered users. You may assess risks based on corresponding qualifications.

  • TTC-6-3-HF-F-M-12DC-UT-I - Surge protection deviceTTC-6-3-HF-F-M-12DC-UT-I - Surge protection device
    TTC-6-3-HF-F-M-12DC-UT-I - Surge protection device 2906769 Surge protection with integrated status indicator and knife disconnection for three signal wires" "
  • IB IL AI 2 SF-230-PAC - Analog moduleIB IL AI 2 SF-230-PAC - Analog module
    IB IL AI 2/SF-230-PAC - Analog module 2861577 Inline , Analog input terminal , Analog inputs : 2 , 0 V ... 10 V , -10 V ... 10 V , 0 mA ... 20 mA , 4 mA" "
  • P-FU 5X20 LED 24-5 - Fuse plugP-FU 5X20 LED 24-5 - Fuse plug
    P-FU 5X20 LED 24-5 - Fuse plug 3209248 Fuse plug , Suitable for terminal blocks with a width of 5.2 mm and above with TG zone , nom ." "
  • SACC-M12MR-5PL M - ConnectorSACC-M12MR-5PL M - Connector
    SACC-M12MR-5PL M - Connector 1424651 Connector , Universal , 5-position , unshielded , Plug angled M12 , coding : A , Push-lock spring connection , knurl" "