Email verifiedBusiness License verified

FL SWITCH 1000T-2POE-GT-2SFP - Industrial Ethernet Switch

2024-05-09T07:27:54Z 
Company: 上海当临自动化科技有限公司
Location: China - Shanghai,上海市青浦区练西公路2850号1幢
Price: Negotiation
Contact: Jason(Manager)
Contact Me:

Tell:+86-19921425125 Mobile:+86-19921425125 Email:126712721066513712116591@113qq00.c7o2m

 

FL SWITCH 1000T-2POE-GT-2SFP Industrial Ethernet Switch

1026765

Unmanaged PoE Switches 1000, 2 SFP ports 100/1000 Mbps, 2 RJ45 ports 10/100/1000 Mbps

Width 42.8 mm
Height 100 mm
Depth 101 mm

Notes on operation Designed to function with all 48 V DC QUINT and TRIO power supplies.
Notes on operation Mode A PoE
Utilization restriction
EMC note EMC: class A product, see manufacturer's declaration in the download area

Mounting type DIN rail mounting

Fiber optic interface
Connection method SFP
Transmission speed 100/1000 Mbps (full duplex)
Transmission physics Depending on the SFP module
Transmission length up to 80 km (Depending on the fiber/SFP module used)
No. of channels 2 (SFP ports)
Ethernet (PoE)
Number of interfaces 2
Connection method RJ45
Transmission speed 10/100/1000 Mbps
Transmission physics Ethernet RJ45
Transmission length 100 m (Between transmitter / receiver)
Signal LEDs LNK/ACT, POE
No. of channels 2 (RJ45 ports)

Product type Switch
Product family Unmanaged PoE Switches 1000
Type Stand-Alone
MTTF 45.9 Years (MIL-HDBK-217F standard, temperature 25°C, operating cycle 100%)
Switch functions
Basic functions Store-and-forward switch, 10/100/1000 Mbps, auto negotiation, redundant power supply, PoE according to IEEE 802.3at/802.3af, jumbo frames up to 10240 bytes, alarm contact
Signal contact control voltage 48 V DC
Signal contact control current 0.5 A
Status and diagnostic indicators LEDs: US1, US2 (redundant voltage supply), Alarm (alarm contact), Link/Activity and PoE per Ethernet port
Additional functions Autonegotiation
Security functions
Basic functions Store-and-forward switch, 10/100/1000 Mbps, auto negotiation, redundant power supply, PoE according to IEEE 802.3at/802.3af, jumbo frames up to 10240 bytes, alarm contact

Local diagnostics US1, US2 Supply voltage Green LED
PoE PoE detection Orange LED
LNK/ACT Link status/data transmission Green/orange LED
Alarm Power failure at US1 or US2/Link failure
Supply
Supply voltage (DC) 55 V DC (redundant)
Supply voltage range 52 V DC ... 57 V DC (>52 V DC for PoE+ recommended)
Power supply connection Via COMBICON, max. conductor cross section 2.5 mm²
Inrush current 25.7 A (52 V DC for 1950 μs)
Residual ripple 3.6 VPP (within the permitted voltage range)
Max. current consumption 1.2 A (Maximum, nominal load)
Typical current consumption 80 mA (at US = 55 V DC)
Function
Signal contact control voltage 48 V DC
Signal contact control current 0.5 A

Connection technology
Connection name Power supply
pluggable yes
Power supply
Connection method Screw connection
Conductor cross section, rigid 0.2 mm² ... 2.5 mm²
Conductor cross section, flexible 0.2 mm² ... 2.5 mm²
Conductor cross section AWG 24 ... 12
Stripping length 7 mm

Ambient conditions
Degree of protection IP30
Ambient temperature (operation) -40 °C ... 75 °C
Ambient temperature (storage/transport) -40 °C ... 85 °C
Permissible humidity (operation) 5 % ... 95 % (non-condensing)
Permissible humidity (storage/transport) 5 % ... 95 % (non-condensing)
Air pressure (operation) 57 kPa ... 108 kPa (up to 4850 m above mean sea level)
Air pressure (storage/transport) 57 kPa ... 108 kPa (up to 4850 m above mean sea level)

Standards/specifications EN 50121 for railway applications

FL SWITCH 1000T-2POE-GT-2SFP - Industrial Ethernet Switch

Disclaimer:All information is provided by registered users. You may assess risks based on corresponding qualifications.

  • TTC-6-3-HF-F-M-12DC-UT-I - Surge protection deviceTTC-6-3-HF-F-M-12DC-UT-I - Surge protection device
    TTC-6-3-HF-F-M-12DC-UT-I - Surge protection device 2906769 Surge protection with integrated status indicator and knife disconnection for three signal wires" "
  • IB IL AI 2 SF-230-PAC - Analog moduleIB IL AI 2 SF-230-PAC - Analog module
    IB IL AI 2/SF-230-PAC - Analog module 2861577 Inline , Analog input terminal , Analog inputs : 2 , 0 V ... 10 V , -10 V ... 10 V , 0 mA ... 20 mA , 4 mA" "
  • P-FU 5X20 LED 24-5 - Fuse plugP-FU 5X20 LED 24-5 - Fuse plug
    P-FU 5X20 LED 24-5 - Fuse plug 3209248 Fuse plug , Suitable for terminal blocks with a width of 5.2 mm and above with TG zone , nom ." "
  • SACC-M12MR-5PL M - ConnectorSACC-M12MR-5PL M - Connector
    SACC-M12MR-5PL M - Connector 1424651 Connector , Universal , 5-position , unshielded , Plug angled M12 , coding : A , Push-lock spring connection , knurl" "