Email verifiedBusiness License verified

EMM 3- 24DC 500AC-16-IFS - Motor management

2024-05-09T07:33:00Z 
Company: 上海当临自动化科技有限公司
Location: China - Shanghai,上海市青浦区练西公路2850号1幢
Price: Negotiation
Contact: Jason(Manager)
Contact Me:

Tell:+86-19921425125 Mobile:+86-19921425125 Email:4567102410651081211136915@q82q.11c6o6m

 

EMM 3- 24DC/500AC-16-IFS Motor management

2297523

Electronic motor management with integrated current transformers up to 16 A - active power measurement for overload and underload monitoring of motors and systems for optimum protection. Freely parameterizable switching and signaling thresholds.


Utilization restriction
EMC note EMC: class A product, see manufacturer's declaration in the download area

Product type Electronic motor manager
Product family CONTACTRON
Operating mode 100% operating factor

Number of phases 3
Maximum power dissipation for nominal condition 5.5 W
Test voltage input/output 8 kV
Supply
Rated control circuit supply voltage US 24 V DC
Control supply voltage range 19.2 V DC ... 30 V DC
Rated control supply current IS 25 mA
Switching threshold 9.6 V DC (“0” signal)
19.2 V DC (“1” signal)
Insulation characteristics
Rated insulation voltage 500 V
Rated surge voltage 6 kV
Overvoltage category III
Degree of pollution 2
Insulation characteristics between the input and output circuits Safe isolation (IEC 60947-1)
Insulation characteristics between the thermistor input and output Basic insulation (IEC 60947-1)

Digital inputs (IN1 - IN4)
Number of inputs 4 (IN1 - IN4)
Rated actuating voltage UC 24 V DC
Rated actuating current IC 3.3 mA
Voltage measuring input V1, V2, V3
Input voltage range 42 V AC ... 575 V AC
Typical input current at UN < 0.5 mA
Current measuring input L1/T1, L2/T2, L3/T3
Typical input current at UN ≤ 16 A
Power measurement
Basic accuracy typ. 2 %
Power range 14 kW
Voltage measurement/star voltage
Basic accuracy typ. 0.75 %
Voltage range 0 V AC ... 350 V AC (Phase-to-neutral voltage)
Current measurement
Basic accuracy typ. 0.5 %
Current range 400 mA ... 16 A
Measuring via Internal current transformer

Output name Acknowledging contacts O1-O4
Note The meaning of the acknowledgement outputs can be freely parameterized, see user manual
Number of outputs 4
Nominal output voltage 24 V DC (semiconductor output)
Output voltage range 19.2 V DC ... 30 V DC
Continuous load current 500 mA
Residual voltage < 200 mV
Protective circuit Suppressor diode
Surge voltage protection > 33 V DC

Control circuits
Connection method Screw connection
Stripping length 8 mm
Screw thread M3
Conductor cross section rigid 0.2 mm² ... 2.5 mm²
Conductor cross section flexible 0.2 mm² ... 2.5 mm²
Conductor cross section AWG 24 ... 14
Load circuit
Connection method Screw connection
Stripping length 8 mm
Screw thread M3
Conductor cross section rigid 0.2 mm² ... 2.5 mm²
Conductor cross section flexible 0.2 mm² ... 2.5 mm²
Conductor cross section AWG 24 ... 14

Status display Yellow LED
Operating voltage display Green LED
Error indication Red LED
Data communication display green LED

EMM 3- 24DC 500AC-16-IFS - Motor management

Disclaimer:All information is provided by registered users. You may assess risks based on corresponding qualifications.

  • TTC-6-3-HF-F-M-12DC-UT-I - Surge protection deviceTTC-6-3-HF-F-M-12DC-UT-I - Surge protection device
    TTC-6-3-HF-F-M-12DC-UT-I - Surge protection device 2906769 Surge protection with integrated status indicator and knife disconnection for three signal wires" "
  • IB IL AI 2 SF-230-PAC - Analog moduleIB IL AI 2 SF-230-PAC - Analog module
    IB IL AI 2/SF-230-PAC - Analog module 2861577 Inline , Analog input terminal , Analog inputs : 2 , 0 V ... 10 V , -10 V ... 10 V , 0 mA ... 20 mA , 4 mA" "
  • P-FU 5X20 LED 24-5 - Fuse plugP-FU 5X20 LED 24-5 - Fuse plug
    P-FU 5X20 LED 24-5 - Fuse plug 3209248 Fuse plug , Suitable for terminal blocks with a width of 5.2 mm and above with TG zone , nom ." "
  • SACC-M12MR-5PL M - ConnectorSACC-M12MR-5PL M - Connector
    SACC-M12MR-5PL M - Connector 1424651 Connector , Universal , 5-position , unshielded , Plug angled M12 , coding : A , Push-lock spring connection , knurl" "