Company: | 上海当临自动化科技有限公司 |
Location: | China - Shanghai,上海市青浦区练西公路2850号1幢 |
Price: | Negotiation |
Contact: | Jason(Manager) |
Contact Me: |
Tell:+86-19921425125 Mobile:+86-19921425125 Email:1071569448812412913485105913@q1011q.119co2m |
CB TM1 6A SFB P - Thermomagnetic device circuit breaker
CB TM1 6A SFB P - Thermomagnetic device circuit breaker
2800841
Thermomagnetic device circuit breaker, 1-pos., tripping characteristic SFB, 1 changeover contact, plug for base element.
General When mounted in rows, the nominal device current can be limited to just 80% or must be overdimensioned accordingly.
Product type Thermomagnetic device circuit breakers
Product family CB TM
Type Male
Number of positions 1
No. of channels 1
Insulation characteristics
Degree of pollution 2
Fuse type Automatic device
General
Rated voltage 50 V DC (IEC 60934)
50 V DC (UL 1077)
50 V DC (UL 508 - with plug-in base)
Rated insulation voltage Ui 277 V AC (UL 1077)
250 V AC (IEC 60934)
Rated current IN 6 A (IEC 60934)
6 A DC (low-induction load according to UL 1077)
6 A DC (low-induction load according to UL 508 - with plug-in base)
Rated surge voltage 2.5 kV (Increased insulation in actuation area)
Insulation resistance Riso > 100 MΩ (500 V DC)
Auxiliary circuit 277 V AC / 0.5 A (Low-induction)
277 V AC / 1 A (Low-induction, maximum of 2000 cycles)
50 V DC / 1 A (Low-induction)
Type of actuation S type
Tripping method TM (thermomagnetic)
Tripping level Trip-free mechanism (positive)
Device resistance 50 mΩ
Required backup fuse 24 A (I > Icn)
Rated short-circuit switching capacity Icn 600 A (50 V DC)
Short-circuit switching capacity 1000 A AC (277 V AC)
1000 A DC (50 V DC)
Dielectric strength 3000 V AC (Actuation area)
1500 V AC (Main to auxiliary circuit)
1500 V AC (Open main circuit)
1000 V AC (Open auxiliary circuit)
Switching cycles, max. 6000 (at 1 x In)
Fuse SFB
Power dissipation 1.8 W (in nominal operation per channel)
Voltage drop 0.29 V (at 1 x In)
Auxiliary contact
Minimum operating voltage Umin DC 10 V
Maximum operating voltage Umax DC 240 V
Maximum operating voltage Umax. AC 240 V
Minimum operating current Imin 10 mA
Max. operating current Imax 1 A
Connection method pluggable
Connection method pluggable
Dimensional drawing
Width 12.3 mm
Height 45 mm
Depth 52 mm
Complete module width 12.3 mm
Complete module height 90 mm
Complete module depth 77.3 mm
Color gray (RAL 7042)
black (RAL 9005)
Flammability rating according to UL 94 V-0
Insulating material group II
Mechanical data
Open side panel No
Ambient conditions
Degree of protection IP30 (Actuation area)
Ambient temperature (operation) -30 °C ... 60 °C
Ambient temperature (storage/transport) -40 °C ... 80 °C
Humidity test 240 h, 95 % RH, 40 °C
Shock (operation) 30g (IEC 60068-2-27, Test Ea)
Vibration (operation) 8g (IEC 60068-2-6, Test Fc)
UL approval
Identification UL Listed UL 508
UL/C-UL Recognized UL 1077
CSA
Identification CSA CAN/CSA-C22.2 No. 235-04
Shipbuilding approval
Identification DNV GL
Standards/specifications EN 60934
Disclaimer:All information is provided by registered users. You may assess risks based on corresponding qualifications.
- fastest single needle bag closing machine for sewing bagsThe bag closing machine head is equipped with continuous ( roll ) feeder and sewing needle for the feeding system ." "
- Standard needle thread double locked bag closing machineSew20 Plain Sew Heavy Duty Bag Closing System machinery Sewing Paper , Poly Woven & Laminated Open Mouth Bags with a Plain Stitch at Up to 20 Bags Per" "
- versatile small volume bagging Sewing machine SystemSewing Paper , Poly Woven & Laminated Open Mouth Bags with a Plain Stitch at Up to 10 Bags Per Minute ." "
- Plain Sew Heavy Duty Bag Closing System machinerylightweight handheld electric bag closer sewing machine The bag stitcher machine is designed with a plastic handle ." "