Email verifiedBusiness License verified

D-LAN-19"-8 - Surge protection device

2024-05-15T07:01:28Z 
Company: 上海当临自动化科技有限公司
Location: China - Shanghai,上海市青浦区练西公路2850号1幢
Price: Negotiation
Contact: Jason(Manager)
Contact Me:

Tell:+86-19921425125 Mobile:+86-19921425125 Email:541511044111840971185651412@q2q3.1213co8m

 

D-LAN-19"-8 Surge protection device

2880163

19" rack with 8 surge protected ports for data interfaces in Ethernet (1000Base-T), Token Ring and FDDI/CDDI networks in acc. with Class D/EN 50173 (CAT5e), connection on the protective device: RJ45 sockets

Product type Surge protection for information technology
Product family DATATRAB
IEC test classification C1
C2
C3
B3
Type 19" rack patch module
Number of positions 8
Surge protection fault message none
Insulation characteristics
Overvoltage category II
Pollution degree 2

Connection method RJ45

Dimensional drawing
Width 483 mm
Height 44 mm
Height unit 1 U
Depth 160 mm

Color Steel / stainless steel
Housing material Sheet steel

Mechanical data
Open side panel No

Direction of action Line-Line & Line-Signal Ground/Shield & Signal Ground/Shield-Earth Ground
Maximum continuous voltage UC (line-line) 6 V DC
Maximum continuous voltage UC (line-earth) 68 V DC (optional: ±6 V DC)
Rated current 1.5 A (25 °C)
Operating effective current IC at UC ≤ 1 mA
Residual current IPE ≤ 1 mA (jumper 2 unplugged)
Nominal discharge current In (8/20) µs (line-line) 350 A
Nominal discharge current In (8/20) µs (line-ground) 350 A
Nominal discharge current In (8/20) µs (shield-ground) 2.5 kA (with insulated housing)
Total discharge current Itotal (8/20) µs 10 kA
Nominal pulse current Ian (10/1000) µs (line-line) 100 A
Nominal pulse current Ian (10/1000) µs (line-earth) 100 A
Output voltage limitation at 1 kV/µs (line-line) static ≤ 20 V
Output voltage limitation at 1 kV/µs (line-earth) static ≤ 30 V (J2 plugged)
≤ 170 V (J2 unplugged)
Output voltage limitation at 1 kV/µs(shield-ground) static ≤ 700 V (with insulated shield)
Residual voltage at In (conductor-conductor) ≤ 65 V
Residual voltage at In (conductor-ground) ≤ 45 V (J2 ON)
≤ 220 V (J2 OFF)
Residual voltage at In (shield-ground) ≤ 700 V
Voltage protection level Up (line-line) ≤ 50 V (C1 - 500 V / 250 A)
Voltage protection level Up (line-earth) ≤ 40 V (C1 - 500 V / 250 A (J2 ON))
≤ 180 V (C1 - 500 V / 250 A (J2 OFF))
Voltage protection level Up (shield-ground) ≤ 800 V (with insulated housing)
Response time tA (line-line) ≤ 1 ns
Response time tA (line-earth) ≤ 1 ns
Response time tA (line-shield) ≤ 100 ns
Input attenuation aE, sym. typ. 1 dB (≤ 100 MHz)
Near-end crosstalk attenuation typ. 36 dB (100 Ω system / 100 MHz)
Cut-off frequency fg (3 dB), sym. in 100 Ω system > 100 MHz
Capacity (Core-Core) typ. 20 pF
Capacity (Core-Earth) typ. 1 pF
Surge protection fault message none
Impulse durability (line-line) C1 - 500 V / 250 A
Impulse durability (line-earth) C1 - 500 V / 250 A
Impulse durability (shield-ground) C2 - 4 kV/2 kA

Ambient conditions
Degree of protection IP20
Ambient temperature (operation) -40 °C ... 80 °C

Air clearances and creepage distances
Standards/regulations DIN VDE 0110-1 / IEC 60664-1
Standards Information technology specification
Standards/regulations IEC 61643-21
DIN EN 50173-1
IEC 61643-21
DIN EN 50173-1
Standards/specifications IEC 61643-21
Note 2000

Mounting type 19" rack

D-LAN-19-8 - Surge protection device

Disclaimer:All information is provided by registered users. You may assess risks based on corresponding qualifications.