Email verifiedBusiness License verified

ELR H5-IES-PT 500AC-3-IFS - Hybrid motor starter

2024-05-16T05:09:34Z 
Company: 上海当临自动化科技有限公司
Location: China - Shanghai,上海市青浦区练西公路2850号1幢
Price: Negotiation
Contact: Jason(Manager)
Contact Me:

Tell:+86-19921425125 Mobile:+86-19921425125 Email:918513413124814959811510597@q1113q.13c5o10m

 

ELR H5-IES-PT/500AC-3-IFS Hybrid motor starter

2905139

Networkable hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 3 A output current, with adjustable overload shutdown, emergency stop function to SIL 3 / PL e and push-in connection, DIN rail connector provided.

Product type Hybrid motor starters
Product family CONTACTRON
Operating mode 100% operating factor

Number of phases 3
Motor starter type Reversing starter
Maximum power dissipation for nominal condition 2.5 W
Switching frequency ≤ 2 Hz (Load-dependent)
Maximum power dissipation 4.1 W
Minimum power dissipation 0.88 W
Coordination type 1
Supply
Rated control circuit supply voltage US 24 V DC
Control supply voltage range 19.2 V DC ... 30 V DC
Rated control supply current IS 60 mA
Protective circuit Surge protection
Reverse polarity protection
Insulation characteristics
Rated insulation voltage 550 V
Rated surge voltage 6 kV
Overvoltage category III
Degree of pollution 2
Insulation characteristics between the control input and control supply voltage, and auxiliary circuit to the main circuit Safe isolation (IEC 60947-1)
Isolation characteristics between the control input and control supply voltage to auxiliary circuit Safe isolation (IEC 60947-1) in the auxiliary circuit ≤ 300 V AC
Emergency tripping
Operate threshold > 33 A
Response time < 0.5 s

Control
Input name Enable input
Note The enable input is compatible with signals with blanking (semiconductor output signals with test pulse with max. 3 ms duration),
unblanking pulses of max. 4 ms are tolerated without adversely affecting the safety function.
Rated actuating voltage UC 24 V DC
Triggering voltage range 19.2 V DC ... 30 V DC
Rated actuating current IC 7 mA
Switching threshold 9.6 V (“0” signal)
19.2 V (“1” signal)
Switching level < 5 V DC (For EMERGENCY STOP)
Typical turn-off time < 30 ms
Protective circuit Reverse polarity protection

AC output
Rated operating voltage Ue 500 V AC
Operating voltage range 42 V AC ... 550 V AC
Rated operating current Ie 3 A (AC-51)
3 A (AC-53a)
Mains frequency 50/60 Hz
Load current range 180 mA ... 3 A (see to derating)
Trigger characteristic in acc. with IEC 60947-4-2 Class 10
Cooling time 20 min. (for auto reset)
Leakage current 0 mA
Protective circuit Surge protection; Varistor

Control circuits
Connection method Push-in connection
Stripping length 10 mm
Conductor cross section rigid 0.2 mm² ... 2.5 mm²
Conductor cross section flexible 0.2 mm² ... 2.5 mm²
Conductor cross section AWG 24 ... 14
Load circuit
Connection method Push-in connection
Stripping length 10 mm
Conductor cross section rigid 0.2 mm² ... 2.5 mm²
Conductor cross section flexible 0.2 mm² ... 2.5 mm²
Conductor cross section AWG 24 ... 14

Status display Yellow LED
Operating voltage display Green LED
Error indication Red LED

Width 22.5 mm
Height 107.5 mm
Depth 114 mm

ELR H5-IES-PT 500AC-3-IFS - Hybrid motor starter