ELR H5-IES-PT 500AC-3-IFS - Hybrid motor starter
ELR H5-IES-PT/500AC-3-IFS - Hybrid motor starter
2905139
Networkable hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 3 A output current, with adjustable overload shutdown, emergency stop function to SIL 3 / PL e and push-in connection, DIN rail connector provided.
Product type Hybrid motor starters
Product family CONTACTRON
Operating mode 100% operating factor
Number of phases 3
Motor starter type Reversing starter
Maximum power dissipation for nominal condition 2.5 W
Switching frequency ≤ 2 Hz (Load-dependent)
Maximum power dissipation 4.1 W
Minimum power dissipation 0.88 W
Coordination type 1
Supply
Rated control circuit supply voltage US 24 V DC
Control supply voltage range 19.2 V DC ... 30 V DC
Rated control supply current IS 60 mA
Protective circuit Surge protection
Reverse polarity protection
Insulation characteristics
Rated insulation voltage 550 V
Rated surge voltage 6 kV
Overvoltage category III
Degree of pollution 2
Insulation characteristics between the control input and control supply voltage, and auxiliary circuit to the main circuit Safe isolation (IEC 60947-1)
Isolation characteristics between the control input and control supply voltage to auxiliary circuit Safe isolation (IEC 60947-1) in the auxiliary circuit ≤ 300 V AC
Emergency tripping
Operate threshold > 33 A
Response time < 0.5 s
Control
Input name Enable input
Note The enable input is compatible with signals with blanking (semiconductor output signals with test pulse with max. 3 ms duration),
unblanking pulses of max. 4 ms are tolerated without adversely affecting the safety function.
Rated actuating voltage UC 24 V DC
Triggering voltage range 19.2 V DC ... 30 V DC
Rated actuating current IC 7 mA
Switching threshold 9.6 V (“0” signal)
19.2 V (“1” signal)
Switching level < 5 V DC (For EMERGENCY STOP)
Typical turn-off time < 30 ms
Protective circuit Reverse polarity protection
AC output
Rated operating voltage Ue 500 V AC
Operating voltage range 42 V AC ... 550 V AC
Rated operating current Ie 3 A (AC-51)
3 A (AC-53a)
Mains frequency 50/60 Hz
Load current range 180 mA ... 3 A (see to derating)
Trigger characteristic in acc. with IEC 60947-4-2 Class 10
Cooling time 20 min. (for auto reset)
Leakage current 0 mA
Protective circuit Surge protection; Varistor
Control circuits
Connection method Push-in connection
Stripping length 10 mm
Conductor cross section rigid 0.2 mm² ... 2.5 mm²
Conductor cross section flexible 0.2 mm² ... 2.5 mm²
Conductor cross section AWG 24 ... 14
Load circuit
Connection method Push-in connection
Stripping length 10 mm
Conductor cross section rigid 0.2 mm² ... 2.5 mm²
Conductor cross section flexible 0.2 mm² ... 2.5 mm²
Conductor cross section AWG 24 ... 14
Status display Yellow LED
Operating voltage display Green LED
Error indication Red LED
Width 22.5 mm
Height 107.5 mm
Depth 114 mm
Disclaimer:All information is provided by registered users. You may assess risks based on corresponding qualifications.
- fastest single needle bag closing machine for sewing bagsThe bag closing machine head is equipped with continuous ( roll ) feeder and sewing needle for the feeding system ." "
- Standard needle thread double locked bag closing machineSew20 Plain Sew Heavy Duty Bag Closing System machinery Sewing Paper , Poly Woven & Laminated Open Mouth Bags with a Plain Stitch at Up to 20 Bags Per" "
- versatile small volume bagging Sewing machine SystemSewing Paper , Poly Woven & Laminated Open Mouth Bags with a Plain Stitch at Up to 10 Bags Per Minute ." "
- Plain Sew Heavy Duty Bag Closing System machinerylightweight handheld electric bag closer sewing machine The bag stitcher machine is designed with a plastic handle ." "