PLC-RPT-230UC/21-21AU/RWF Relay Module

2900345

PLC-INTERFACE for railway applications, consisting of basic terminal block with Push-in connection and plug-in miniature relay with multi-layer gold contact, range: 0.75 x UN to 1.15 x UN, nominal input frequency 16.7 Hz, 2 changeover contacts, input voltage 230 V AC

Product type Relay Module
Product family PLC-INTERFACE
Application Railway applications
Operating mode 100% operating factor
Mechanical service life approx. 3x 107 cycles
Insulation characteristics
Insulation Basic insulation
Insulation characteristics: Air clearances and creepage distances between the power circuits
Insulation Basic insulation
Overvoltage category III
Pollution degree 2

Maximum power dissipation for nominal condition 1.1 W
Test voltage (Winding/contact) 6 kV (50 Hz, 1 min., winding/contact)
Air clearances and creepage distances between the power circuits
Rated insulation voltage 250 V AC
Rated surge voltage 6 kV

Coil side
Nominal input voltage UN 230 V AC
Input voltage range 172.5 V AC ... 264.5 V AC (20 °C)
Mains frequency 16.67 Hz
Drive and function monostable
Drive (polarity) polarized
Typical input current at UN 4.8 mA (with AC)
Typical response time 20 ms
Typical release time 60 ms
Coil voltage 110 V DC
Protective circuit Bridge rectifier
Operating voltage display Yellow LED

Switching
Contact switching type 2 changeover contacts
Type of switch contact Single contact
Contact material AgNi, hard gold-plated
Note If the specified maximum values are exceeded, the gold plating is destroyed. The AgNi contact values are then valid for further operation; a reduction in length of service life is to be expected.
Maximum switching voltage 30 V AC
36 V DC
Minimum switching voltage 100 mV
Limiting continuous current 50 mA
Maximum inrush current 50 mA
Min. switching current 1 mA
Interrupting rating (ohmic load) max. 1.2 W (24 V DC)
Switching capacity 2 A (24 V (DC13), in acc. with DIN VDE 0660/IEC 60947)
0.2 A (220 V DC / 230 V AC (DC13), in acc. with DIN VDE 0660/IEC 60947)
3 A (220 V DC / 230 V AC (AC15), in acc. with DIN EVDE 0660/IEC 60947)
Switching: when the gold layer is destroyed
Note the following values are applicable if a gold layer is destroyed
Contact material AgNi
Maximum switching voltage 250 V AC/DC (Separating plate PLC-ATP must be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal blocks in adjacent modules.)
Minimum switching voltage 5 V AC/DC
Limiting continuous current 6 A
Maximum inrush current 8 A
Min. switching current 10 mA
Interrupting rating (ohmic load) max. 140 W (at 24 V DC)
85 W (at 48 V DC)
60 W (at 60 V DC)
44 W (at 110 V DC)
60 W (at 220 V DC)
1500 VA (for 250 V AC)
Switching capacity 2 A (at 24 V, DC13)
0.2 A (at 110 V, DC13)
0.2 A (at 250 V, DC13)
2 A (at 24 V, AC15)
2 A (at 120 V, AC15)
2 A (at 250 V, AC15)

Connection method Push-in connection
Stripping length 10 mm
Conductor cross section rigid 0.14 mm² ... 2.5 mm²
Conductor cross section flexible 0.14 mm² ... 2.5 mm²
0.2 mm² ... 2.5 mm² (Single ferrule)
2x 0.5 mm² ... 1 mm² (TWIN ferrule)
Conductor cross section AWG 26 ... 14

Width 14 mm
Height 80 mm
Depth 94 mm

Color gray (RAL 7042)
Flammability rating according to UL 94 V0 (Housing)

Ambient conditions
Degree of protection (Relay) RT III (Relay)
Degree of protection (Relay base) IP20 (Relay base)
Ambient temperature (operation) -25 °C ... 55 °C
Ambient temperature (storage/transport) -40 °C ... 85 °C

CE
Certificate CE-compliant
Corrosive gas test
Identification ISA-S71.04. G3 Harsh Group
EN 60068-2-60

Low Voltage Directive Conformance with Low Voltage Directive
Electromagnetic compatibility Conformance with EMC directive

Air clearances and creepage distances between the power circuits
Standards/regulations IEC 60947-5-1