PSR-SPP-230AC/ESAM2/3X1/1X2/B Safety relays

2901431

Safety relay for emergency stop and safety door up to SIL 1, Cat. 1, PL c, depending on the application up to SIL 3, Cat. 4, PL e, single-channel operation, 3 enabling current paths, nominal input voltage of 230 V AC/DC, pluggable Push-in terminal block


Product type Safety relays
Product family PSRclassic
Application Emergency stop
Safety door
Mechanical service life approx. 107 cycles
Relay type Electromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3

Maximum power dissipation for nominal condition 2.88 W
Nominal operating mode 100% operating factor
Air clearances and creepage distances between the power circuits
Rated insulation voltage 250 V AC
Rated surge voltage/insulation 4 kV / basic insulation (safe isolation, reinforced insulation, and 6 kV between A1-A2/logic/enabling and signaling current paths)

General
Rated control circuit supply voltage US 230 V AC -15 % / +10 %
Rated control supply current IS 22 mA
Voltage at input/start and feedback circuit ~ 24 V DC
Typical response time 50 ms (manual start)
300 ms (automatic start)
Typ. starting time with Us 300 ms (when controlled via A1 or S11/S12)
Typical release time 20 ms (when controlled via S11/S12)
150 ms (when controlled via A1)
Recovery time 1 s
Maximum switching frequency 0.5 Hz
Protective circuit Surge protection; Suppressor diode
Surge protection; Varistor
Max. permissible overall conductor resistance 50 Ω

Contact switching type 3 enabling current paths
1 signaling current path
Contact material AgSnO2, gold-flashed
Maximum switching voltage 250 V AC/DC
Minimum switching voltage 10 V AC/DC
Limiting continuous current 6 A (Enabling current paths)
5 A (Signaling current path)
Maximum inrush current 6 A
Inrush current, minimum 10 mA
Sq. Total current 72 A2
Interrupting rating (ohmic load) max. 144 W (at 24 V DC)
230 W (at 48 V DC)
68 W (at 110 V DC)
88 W (at 220 V DC)
2000 VA (for 250 V AC)
Maximum interrupting rating (inductive load) 48 W (at 24 V DC)
40 W (at 48 V DC)
35 W (at 110 V DC)
33 W (at 220 V DC)
Switching capacity min. 100 mW
Switching capacity (360/h cycles) 6 A (24 V DC)
5 A (230 V AC)
Switching capacity (3600/h cycles) 3 A (24 V (DC13))
3 A (230 V (AC 15))
Output fuse 10 A gL/gG NEOZED (Enabling current paths)
6 A gL/gG NEOZED (Signaling current paths)

Connection technology
pluggable yes
Conductor connection
Connection method Push-in connection
Conductor cross section rigid 0.2 mm² ... 1.5 mm²
Conductor cross section flexible 0.2 mm² ... 1.5 mm²
Conductor cross section, flexible, with ferrule, with plastic sleeve 0.25 mm² ... 1.5 mm² (only together with CRIMPFOX 6)
Conductor cross section flexible, with ferrule without plastic sleeve 0.25 mm² ... 1.5 mm² (only together with CRIMPFOX 6)
Conductor cross-section AWG 24 ... 16
Stripping length 8 mm

Status display 2 x green LEDs
Operating voltage display 1 x green LED

Width 22.5 mm
Height 112 mm
Depth 114.5 mm

Housing material Polyamide

Safety data
Stop category 0
Safety data: EN ISO 13849
Category 1 (up to Cat. 4 depending on the application)
Performance level (PL) c (up to PL e depending on the application)