Email verifiedBusiness License verified

PLC-RPT- 24UC 21-21 MS - Relay Module

2024-05-17T07:00:48Z 
Company: 上海当临自动化科技有限公司
Location: China - Shanghai,上海市青浦区练西公路2850号1幢
Price: Negotiation
Contact: Jason(Manager)
Contact Me:

Tell:+86-19921425125 Mobile:+86-19921425125 Email:1019354121248010497890558@6q3q20.c3o12m

 

PLC-RPT- 24UC/21-21/MS Relay Module

2910520

PLC-INTERFACE, consisting of a relay base and pluggable power contact relay with manual operation, integrated status LED, Push-in connection, 2 changeover contacts, Bridge rectifier, Input voltage: 24 V AC/DC


Product type Relay Module
Product family PLC-INTERFACE
Application Palm switch
Operating mode 100% operating factor
Mechanical service life 5x 106 cycles
Insulation characteristics
Insulation Safe isolation, reinforced insulation
Insulation characteristics: Air clearances and creepage distances between the power circuits
Insulation Safe isolation, reinforced insulation
Overvoltage category III
Pollution degree 2

Maximum power dissipation for nominal condition 0.44 W
Test voltage (Winding/contact) 4 kVrms (50 Hz, 1 min.)
Test voltage (Changeover contact/changeover contact) 2.5 kVrms (50 Hz, 1 min.)
Air clearances and creepage distances between the power circuits
Rated insulation voltage 250 V AC
Rated surge voltage 6 kV

Coil side
Nominal input voltage UN 24 V AC/DC
Input voltage range 20.6 V AC/DC ... 33.6 V AC/DC (20 °C)
() 24 V DC
Drive and function monostable
Drive (polarity) polarized
Typical input current at UN 18 mA
Typical response time 3 ms ... 15 ms
Typical release time range 3 ms ... 15 ms
Coil voltage 24 V DC
Protective circuit Bridge rectifier; Bridge rectifier
Operating voltage display Yellow LED

Switching
Contact switching type 2 changeover contacts
Type of switch contact Single contact
Contact material AgNi
Maximum switching voltage 250 V AC/DC (The separating plate PLC-ATP should be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal blocks in adjacent modules. Potential bridging is then carried out with FBST 8-PLC... or ...FBST 500...)
Minimum switching voltage 12 V (10 mA)
Limiting continuous current 6 A
Maximum inrush current 12 A (20 ms)
Min. switching current 10 mA (12 V)
Interrupting rating (ohmic load) max. 192 W (24 V DC)
62 W (48 V DC)
42 W (60 V DC)
55 W (110 V DC)
66 W (220 V DC)
2000 VA (250 V AC)
Switching capacity 1 A (24 V, DC13)
1.5 A (230 V, AC15)

Connection method Push-in connection
Stripping length 10 mm
Conductor cross section rigid 0.14 mm² ... 2.5 mm²
Conductor cross section flexible 0.14 mm² ... 2.5 mm²
0.2 mm² ... 2.5 mm² (Single ferrule)
2x 0.5 mm² ... 1 mm² (TWIN ferrule)
Conductor cross section AWG 26 ... 14

Width 14 mm
Height 80 mm
Depth 104 mm

Color gray (RAL 7042)
Flammability rating according to UL 94 V0 (Housing)

Ambient conditions
Degree of protection (Relay) RT II
Degree of protection (Relay base) IP20
Degree of protection (Installation location) ≥ IP54
Ambient temperature (operation) -40 °C ... 60 °C
Ambient temperature (storage/transport) -40 °C ... 85 °C
Altitude ≤ 2000 m

CE
Certificate CE-compliant

PLC-RPT- 24UC 21-21 MS - Relay Module