RIF-1-RPT-LV-230AC 2X21MS - Relay Module
RIF-1-RPT-LV-230AC/2X21MS - Relay Module
2905292
Preassembled relay module with Push-in connection, consisting of: relay base, relay retaining bracket, plug-in interference suppression module, and power contact relay with test button and integrated status LED. Contact switching type: 2 changeover contacts. Input voltage: 230 V AC
Product type Relay Module
Product family RIFLINE complete
Application Universal
Palm switch
Operating mode 100% operating factor
Mechanical service life approx. 5x 106 cycles
Insulation characteristics
Insulation Safe isolation between input and output
Basic insulation between the changeover contacts
Insulation characteristics
Insulation Safe isolation between input and output
Basic insulation between the changeover contacts
Overvoltage category III
Pollution degree 2
Service life electrical see diagram
Maximum power dissipation for nominal condition 0.81 W
Test voltage (Winding/contact) 4 kVrms (50 Hz, 1 min., winding/contact)
Test voltage (Changeover contact/changeover contact) 2.5 kVrms (50 Hz, 1 min., changeover contact/changeover contact)
Rated insulation voltage 250 V AC
Rated surge voltage 6 kV (Input/output)
4 kV (between the changeover contacts)
Coil side
Nominal input voltage UN 230 V AC (50/60 Hz)
Input voltage range 184 V AC ... 253 V AC (20 °C)
Input voltage range in reference to UN see diagram
Mains frequency 50/60 Hz
Drive and function monostable
Drive (polarity) polarized
Typical input current at UN 3.5 mA
Typical response time 4 ms ... 10 ms
Typical release time range 3 ms ... 20 ms
Coil voltage 230 V AC
Protective circuit Varistor
Operating voltage display Yellow LED
Switching
Contact switching type 2 changeover contacts
Type of switch contact Single contact
Contact material AgNi
Maximum switching voltage 250 V AC/DC
Minimum switching voltage 12 V (10 mA)
Limiting continuous current 5 A (see diagram)
Maximum inrush current 16 A (20 ms, N/O contacts)
Min. switching current 10 mA (12 V)
Interrupting rating (ohmic load) max. 192 W (at 24 V DC)
62 W (at 48 V DC)
42 W (at 60 V DC)
55 W (at 110 V DC)
66 W (at 220 V DC)
2000 VA (for 250 V AC)
Switching capacity min. 120 mW
Utilization category CB Scheme (IEC 60947-5-1) AC15, 1.5 A/250 V (N/O contact)
DC13, 1 A/24 V (N/O contact)
Connection method Push-in connection
Stripping length 8 mm
Conductor cross section rigid 0.14 mm² ... 1.5 mm²
Conductor cross section flexible 0.14 mm² ... 1.5 mm²
0.14 mm² ... 1.5 mm² (Ferrule with plastic sleeve)
0.14 mm² ... 1 mm² (Ferrule with plastic sleeve, two conductors on double terminal block)
Conductor cross section AWG 26 ... 16 (solid)
26 ... 16 (flexible)
Drill hole
Diameter 3.2 mm
Width 16 mm
Height 96 mm
Depth 75 mm
Color gray (RAL 7042)
Flammability rating according to UL 94 V2 (Housing)
Disclaimer:All information is provided by registered users. You may assess risks based on corresponding qualifications.
- Crane weighing scale for heavy loads equipmentMultiple Units : These scales can display weight measurements in various units , such as kilograms , pounds , ounces , or newtons , depending on the scale" "
- 833140N Digital Hang LED Scale Hanging Crane ScaleDigital Display : Most crane scales are equipped with a digital display that provides real-time weight readings ." "
- Rhorawill Crane Scale 300kgs Double Accuracy ElectronicCrane weighing scales , also known as crane scales or crane load cells , are specialized weighing devices designed for the purpose of lifting and weighing" "
- OCS-T-300kg Digital Hanging ScaleLCD digital crane mini hanging scale for commercial use The mini hanging scale features a die-cast aluminum casing for added strength ." "