Email verifiedBusiness License verified

VIP-PA-FLK50 4X14、4,0M S7 - Front adapter

2024-05-20T05:21:39Z 
Company: 上海当临自动化科技有限公司
Location: China - Shanghai,上海市青浦区练西公路2850号1幢
Price: Negotiation
Contact: Jason(Manager)
Contact Me:

Tell:+86-19921425125 Mobile:+86-19921425125 Email:6110354147484124948711555@11q10q811.c8o0m

 

VIP-PA-FLK50/4X14/ 4,0M/S7 Front adapter

2322605

VIP VARIOFACE front adapter, with connected system cables for SMATIC S7-300, 4 x 8 channels can be connected


Product type Front adapter
Product family VARIOFACE Professional
Insulation characteristics
Insulation Functional insulation
Insulation characteristics: Air clearances and creepage distances
Insulation Functional insulation
Overvoltage category II
Pollution degree 2

Operating voltage (AC) ≤ 30 V AC
Operating voltage (DC) ≤ 60 V DC
Current (per branch) ≤ 1 A
Current (Voltage supply) ≤ 8 A
Current (per byte) ≤ 2 A
Air clearances and creepage distances
Rated insulation voltage 63 V
Rated surge voltage 0.6 kV
Supported controller SIEMENS S7-300 / ET 200 M
Suitable I/O card CPU 313C
CPU 313C-2PtP
CPU 313C-2DP
CPU 314C-2PtP
CPU 314C-2DP
6ES7321-1BL00-0AA0
6ES7322-1BL00-0AA0
6ES7322-8BH01-0AB0
6ES7322-8BH10-0AB0
6ES7323-1BL00-0AA0
6ES7331-7NF00-0AB0
6ES7331-7NF10-0AB0
6ES7331-7PF01-0AB0
6ES7331-7PF11-0AB0
6ES7350-2AH01-0AE0
6ES7357-4AH01-0AE0
6ES7331-1KF02-0AB0

Connection 1 (control level)
Connection method Plug-in connection
Number of positions 40
Note Can be plugged onto 40-pos. I/O modules
Connection 2 (field level)
Connection in acc. with standard IEC 60603-13
Connection method IDC/FLK socket strip
Number of connections 4
Number of positions 14
Insertion/withdrawal cycles < 50
Pitch 2.54 mm
Connection 3 (supply)
Connection method Push-in spring connection
Stripping length 10 mm
Number of connections 2
Number of positions 4
Conductor cross section rigid 0.2 mm² ... 2.5 mm²
Conductor cross section flexible 0.2 mm² ... 2.5 mm²
0.25 mm² ... 2.5 mm² (Ferrule without plastic sleeve)
0.25 mm² ... 1 mm² (Ferrule with plastic sleeve)
Conductor cross section flexible (2 conductors with same cross section) 0.5 mm² ... 1 mm² (TWIN ferrule with plastic sleeve)
Conductor cross section AWG 24 ... 12
Pitch 5 mm

Cable
Length 4 m

14X0.14 [PVC]
UL AWM Style 2464/1061
Number of positions 14
Shielded no
Cable type 14X0.14 [PVC]
Conductor type Round cable set
Conductor structure signal line 7x 0.16 mm
AWG signal line 26
Conductor cross section 14x 0.14 mm²
Wire diameter incl. insulation 1 mm ±0.03 mm
External cable diameter 6.40 mm ±0.4 mm
Outer sheath, material Semi-rigid PVC
External sheath, color gray
Conductor material Tin-plated Cu litz wires
Cable resistance ≤ 145 Ω/km (20 °C)
Insulation resistance ≥ 20 MΩ*km (20 °C)
Smallest bending radius, fixed installation 55 mm
Smallest bending radius, movable installation 104 mm
Max. bending cycles 5000 (at a radius of ≥ 15x outside diameter)
Halogen-free no
Flame resistance IEC 60332-1-2 (raw cable)
VDE 0842, Part 332-1-2 (raw cable)
IEC 60332-3-22 (raw cable)
UL VW-1
CSA FT-1
Resistance to oil can withstand occasional splashes (raw cable)

VIP-PA-FLK50 4X14、4,0M S7 - Front adapter