RIF-1-RPT-LDP-24DC/2X21/FG Relay Module

2908215

Preassembled relay module with Push-in connection, consisting of: relay base, safety relay with force-guided contacts in accordance with DIN EN 61810-3, plug-in display/interference suppression module, and retaining bracket, contact switching type: 2 changeover contacts, input voltage: 24 V DC


Product type Relay Module
Product family RIFLINE complete
Application Forcibly guided contacts
Operating mode 100% operating factor
Mechanical service life approx. 107 cycles
B10d 600000 Cycles (AC1; 250 V / 6 A; 1 NO)
900000 Cycles (AC1; 250 V / 3 A; 1 NO)
1800000 Cycles (AC1; 250 V / 1,5 A; 1 NO)
300000 Cycles (DC13; 24 V / 3 A; 1 NO)
1000000 Cycles (DC13; 24 V / 1,5 A; 1 NO)
3000000 Cycles (DC13; 24 V / 0,75 A; 1 NO)
Insulation characteristics: Air clearances and creepage distances between the power circuits
Insulation Safe isolation between input and output
Basic insulation between the changeover contacts
Overvoltage category III
Pollution degree 2

Maximum power dissipation for nominal condition 0.72 W
Test voltage (Winding/contact) 4 kVrms (50 Hz, 60 s)
Test voltage () 1.5 kVrms (50 Hz, 60 s)
Test voltage (Changeover contact/changeover contact) 2.5 kVrms (50 Hz, 60 s)
Air clearances and creepage distances between the power circuits
Rated insulation voltage 250 V AC (Input/output)
Rated surge voltage 6 kV (Input/output)
4 kV (between the changeover contacts)
Short-circuit protection device
Current 10 A (RT28-32)
Voltage 500 V (SCPD)
Short-circuit current 1 kA (conditional short-circuit current)

Coil side
Nominal operating voltage UN 24 V DC
Input voltage range 20.4 V DC ... 28.8 V DC (20 °C)
Input voltage range in reference to UN see diagram
Drive and function monostable
Drive (polarity) polarized
Typical input current at UN 30 mA
Typical response time 15 ms
Typical release time 10 ms
Coil voltage 24 V DC
Protective circuit Freewheeling diode
Operating voltage display Yellow LED

Switching
Contact switching type 2 changeover contacts, forcibly actuated
Type of switch contact Single contact
Contact material AgSnO
Maximum switching voltage 250 V AC/DC
Limiting continuous current 6 A
Interrupting rating (ohmic load) max. 144 W (24 V DC)
58 W (48 V DC)
54 W (60 V DC)
55 W (110 V DC)
55 W (220 V DC)
1500 VA (250 V AC)
Utilization category CB Scheme (IEC 60947-5-1) AC15, 3 A/240 V (N/O contact)