Company: | 上海当临自动化科技有限公司 |
Location: | China - Shanghai,上海市青浦区练西公路2850号1幢 |
Price: | Negotiation |
Contact: | Jason(Manager) |
Contact Me: |
Tell:+86-19921425125 Mobile:+86-19921425125 Email:13115106441214846098005512@13q5q211.c68om |
SACCBP-MSB-2CON-PG9 0,5-910SCO - Device connector rear mounting
SACCBP-MSB-2CON-PG9/0,5-910SCO - Device connector rear mounting
1437481
Device connector rear mounting, PROFIBUS, 2-position, PUR halogen-free, red lilac RAL 4001, shielded, Pin, straight, M12-SPEEDCON, coding: B, on free cable end, Rear mounting, Cable connection, cable length: 0.5 m, PROFIBUS, Alternative product in accordance with RoHS II without Exemption 6c (Pb < 0.1 %) item no.: 1239654
Notes on operation The electrical and mechanical data specified assume that the connector pair is correctly locked and mounted. If the connector is unlocked and if there is a danger of contamination, the connector must be sealed using a protective cap > IP54. Influences arising from litz wires, cables or PCB assembly must also be taken into consideration.
Order information: Lock nut is included in the scope of delivery
Safety note
Safety note WARNING: The connectors may not be plugged in or disconnected under load. Ignoring the warning or improper use may damage persons and/or property.
• WARNING: Commission properly functioning products only. The products must be regularly inspected for damage. Decommission defective products immediately. Replace damaged products. Repairs are not possible.
• WARNING: Only electrically qualified personnel may install and operate the product. They must observe the following safety notes. The qualified personnel must be familiar with the basics of electrical engineering. They must be able to recognize and prevent danger. The relevant symbol on the packaging indicates that only personnel familiar with electrical engineering are allowed to install and operate the product.
• The products are suitable for applications in plant, controller, and electrical device engineering.
• When operating the connectors in outdoor applications, they must be separately protected against environmental influences.
• Assembled products may not be manipulated or improperly opened.
• Only use mating connectors that are specified in the technical data of the standards listed (e.g. the ones listed in the product accessories online at phoenixcontact.com/products).
• When using the product in direct connection with third-party manufacturers, the user is responsible.
• For operating voltages > 50 V AC, conductive connector housings must be grounded
• Ensure that when laying the cable, the tensile load on the connectors does not exceed the upper limit specified in the standards.
• Observe the corresponding technical data. You will find information:
o On the product
o On the packing label
o In the supplied documentation
o Online at phoenixcontact.com/products under the product
• Only use tools recommended by Phoenix Contact
• Use a protective cap to protect connectors that are not in use. The suitable accessories are available online in the accessory section of the product at phoenixcontact.com/products
• Ensure that the protective or functional ground has been properly connected.
• VDE 0100/1.97 § 411.1.3.2 and DIN EN 60 204/11.98 § 14.1.3 are applicable when combining several circuits in a cable and/or connector
• The connector warms up in normal operation. Depending on the ambient conditions, the surface of the connector can continue to warm up. In this case, the user is responsible for posting warnings (e.g. DIN EN ISO 13732-1:2008-12).
Mounting type Rear mounting
Product type Circular connectors (device side)
Sensor type PROFIBUS
Number of positions 2
No. of cable outlets 1
Shielded yes
Coding B
Thread type M12
Insulation characteristics
Overvoltage category II
Degree of pollution 3
Flammability rating according to UL 94 V0
Seal material FKM
Contact material CuZn
Contact surface material Ni/Au
Contact carrier material PA 6.6
Material for screw connection Zinc die-cast, nickel-plated
Outer sheath, material PUR
Rated surge voltage 1.5 kV
Contact resistance ≤ 3 mΩ
Insulation resistance ≥ 100 MΩ
Nominal voltage UN 48 V AC
60 V DC
Nominal current IN 4 A (Plug/socket in accordance with IEC 61076-2-101, cable technical data is to be observed)
Transmission medium Copper
Conductor connection
Connection method Cable connection
Contact connection type Pin
Tightening torque 2 Nm ... 3 Nm
Mechanical data
Insertion/withdrawal cycles > 100
Connection 1
Head design Pin
Head cable outlet straight
Head thread type M12
Head locking type SPEEDCON
Coding B
Disclaimer:All information is provided by registered users. You may assess risks based on corresponding qualifications.
- Crane weighing scale for heavy loads equipmentMultiple Units : These scales can display weight measurements in various units , such as kilograms , pounds , ounces , or newtons , depending on the scale" "
- 833140N Digital Hang LED Scale Hanging Crane ScaleDigital Display : Most crane scales are equipped with a digital display that provides real-time weight readings ." "
- Rhorawill Crane Scale 300kgs Double Accuracy ElectronicCrane weighing scales , also known as crane scales or crane load cells , are specialized weighing devices designed for the purpose of lifting and weighing" "
- OCS-T-300kg Digital Hanging ScaleLCD digital crane mini hanging scale for commercial use The mini hanging scale features a die-cast aluminum casing for added strength ." "