Email verifiedBusiness License verified

PLC-RSC-120UC 21-21AU - Relay Module

2024-05-22T02:50:26Z 
Company: 上海当临自动化科技有限公司
Location: China - Shanghai,上海市青浦区练西公路2850号1幢
Price: Negotiation
Contact: Jason(Manager)
Contact Me:

Tell:+86-19921425125 Mobile:+86-19921425125 Email:41013541374889491685035@7q69q.14c2o7m

 

PLC-RSC-120UC/21-21AU Relay Module

2967138

PLC-INTERFACE, consisting of PLC-BSC.../21 basic terminal block with screw connection and plug-in miniature relay with multi-layer gold contact, for mounting on DIN rail NS 35/7,5, 2 changeover contacts, input voltage 120 V AC/110 V DC

Product type Relay Module
Product family PLC-INTERFACE
Application Universal
Operating mode 100% operating factor
Mechanical service life 3x 107 cycles
Insulation characteristics
Insulation Basic insulation
Insulation characteristics
Insulation Basic insulation
Overvoltage category III
Pollution degree 3

Maximum power dissipation for nominal condition 0.54 W
Test voltage (Winding/contact) 4 kV AC (50 Hz, 1 min., winding/contact)
Test voltage (Changeover contact/changeover contact) 2.5 kV AC (50 Hz, 1 min., changeover contact/changeover contact)
Rated surge voltage 6 kV

Coil side
Nominal input voltage UN 120 V AC
110 V DC
Input voltage range 102 V AC ... 168 V AC (20 °C)
85.8 V DC ... 154 V DC (20 °C)
() 110 V DC
Drive and function monostable
Drive (polarity) polarized
Typical input current at UN 4.5 mA (at UN = 120 V AC)
4.2 mA (at UN = 110 V DC)
Typical response time 7 ms
Typical release time 10 ms
Protective circuit Bridge rectifier; Bridge rectifier
Operating voltage display Yellow LED

Switching
Contact switching type 2 changeover contacts
Type of switch contact Single contact
Contact material AgNi, hard gold-plated
Maximum switching voltage 30 V AC
36 V DC
Minimum switching voltage 100 mV (10 mA)
Limiting continuous current 50 mA
Maximum inrush current 50 mA
Min. switching current 1 mA (24 V)
Interrupting rating (ohmic load) max. 1.2 W (at 24 V DC)
Switching: when the gold layer is destroyed
Note the following values are applicable if a gold layer is destroyed
Maximum switching voltage 250 V AC/DC
Minimum switching voltage 5 V AC/DC
Limiting continuous current 6 A
Maximum inrush current 15 A (300 ms)
Min. switching current 10 mA
Interrupting rating (ohmic load) max. 140 W (at 24 V DC)
85 W (at 48 V DC)
60 W (at 60 V DC)
44 W (at 110 V DC)
60 W (at 220 V DC)
1500 VA (for 250 V AC)
Switching capacity 2 A (at 24 V, DC13)
0.2 A (at 110 V, DC13)
0.2 A (at 250 V, DC13)
2 A (at 24 V, AC15)
2 A (at 120 V, AC15)
2 A (at 250 V, AC15)

Connection method Screw connection
Stripping length 8 mm
Screw thread M3
Conductor cross section rigid 0.14 mm² ... 2.5 mm²
Conductor cross section flexible 0.14 mm² ... 2.5 mm²
0.2 mm² ... 2.5 mm² (Single ferrule)
2x 0.5 mm² ... 1.5 mm² (TWIN ferrule)
Conductor cross section AWG 26 ... 14
Tightening torque 0.6 Nm ... 0.8 Nm

Width 14 mm
Height 80 mm
Depth 94 mm

PLC-RSC-120UC 21-21AU - Relay Module

Disclaimer:All information is provided by registered users. You may assess risks based on corresponding qualifications.

  • KM0-M711D-00X YAMAHA 33A NOZZLEKM0-M711D-00X YAMAHA 33A NOZZLE
    KM0-M711D-00X YAMAHA 33A NOZZLE www ( dot ) smt-cn ( dot ) com Skype :14786692449 sale (at ) hysmt ( dot ) cn Other yamaha NOZZLE :" "
  • KM0-M711A-31X YAMAHA 31A NOZZLEKM0-M711A-31X YAMAHA 31A NOZZLE
    KM0-M711A-31X YAMAHA 31A NOZZLE www ( dot ) smt-cn ( dot ) com Skype :14786692449 sale (at ) hysmt ( dot ) cn Other yamaha parts : YAMAHA YV100X" "
  • KLW-M3712-02 protect cover for feeder trolleyKLW-M3712-02 protect cover for feeder trolley
    KLW-M3712-02 protect cover for feeder trolley www ( dot ) smt-cn ( dot ) com Skype :14786692449 sale (at ) hysmt ( dot ) cn Other yamaha parts :" "
  • KLW-M741S-A00 SHAFT,SPAREKLW-M741S-A00 SHAFT,SPARE
    KLW-M741S-A00 SHAFT,SPARE www ( dot ) smt-cn ( dot ) com Skype :14786692449 sale (at ) hysmt ( dot ) cn Other yamaha parts : No. Part No. Part Name Q'ty" "