PLC-RPT- 12DC 21AU - Relay Module
PLC-RPT- 12DC/21AU - Relay Module
2900317
PLC-INTERFACE, consisting of PLC-BPT.../21 basic terminal block with Push-in connection and plug-in miniature relay with multi-layer gold contact, for mounting on DIN rail NS 35/7,5, 1 changeover contact, input voltage 12 V DC
Product type Relay Module
Product family PLC-INTERFACE
Application Universal
Operating mode 100% operating factor
Mechanical service life 2x 107 cycles
Maximum power dissipation for nominal condition 0.18 W
Test voltage (Winding/contact) 4 kV AC (50 Hz, 1 min., winding/contact)
Insulation characteristics: Coil/contact
Rated insulation voltage 250 V
Rated impulse withstand voltage 6 kV
Overvoltage category III
Degree of pollution 3
Coil side
Nominal input voltage UN 12 V DC
Input voltage range 9.7 V DC ... 16.8 V DC (20 °C)
() 12 V DC
Drive and function monostable
Drive (polarity) polarized
Typical input current at UN 15.3 mA
Typical response time 5 ms
Typical release time 8 ms
Protective circuit Reverse polarity protection; Polarity protection diode
Surge protection; Freewheeling diode
Operating voltage display Yellow LED
Switching
Contact switching type 1 changeover contact
Type of switch contact Single contact
Contact material AgSnO, hard gold-plated
Maximum switching voltage 30 V AC
36 V DC
Minimum switching voltage 100 mV (10 mA)
Limiting continuous current 50 mA
Maximum inrush current 50 mA
Min. switching current 1 mA (24 V)
Short-circuit current 200 A (conditional short-circuit current)
Interrupting rating (ohmic load) max. 1.2 W (at 24 V DC)
Output fuse 4 A gL/gG NEOZED
Switching: when the gold layer is destroyed
Note the following values are applicable if a gold layer is destroyed
Maximum switching voltage 250 V AC/DC
Minimum switching voltage 5 V (at 100 mA)
Limiting continuous current 6 A
Min. switching current 10 mA (at 12 V)
Interrupting rating (ohmic load) max. 140 W (at 24 V DC)
20 W (at 48 V DC)
18 W (at 60 V DC)
23 W (at 110 V DC)
40 W (at 220 V DC)
1500 VA (for 250 V AC)
Switching capacity 2 A (at 24 V, DC13)
0.2 A (at 110 V, DC13)
0.1 A (at 220 V, DC13)
3 A (at 24 V, AC15)
3 A (at 120 V, AC15)
3 A (at 230 V, AC15)
Connection method Push-in connection
Stripping length 10 mm
Conductor cross section rigid 0.14 mm² ... 2.5 mm²
Conductor cross section flexible 0.14 mm² ... 2.5 mm²
0.2 mm² ... 2.5 mm² (Single ferrule)
2x 0.5 mm² ... 1 mm² (TWIN ferrule)
Conductor cross section AWG 26 ... 14
Width 6.2 mm
Height 80 mm
Depth 94 mm
Disclaimer:All information is provided by registered users. You may assess risks based on corresponding qualifications.
- KM0-M711D-00X YAMAHA 33A NOZZLEKM0-M711D-00X YAMAHA 33A NOZZLE www ( dot ) smt-cn ( dot ) com Skype :14786692449 sale (at ) hysmt ( dot ) cn Other yamaha NOZZLE :" "
- KM0-M711A-31X YAMAHA 31A NOZZLEKM0-M711A-31X YAMAHA 31A NOZZLE www ( dot ) smt-cn ( dot ) com Skype :14786692449 sale (at ) hysmt ( dot ) cn Other yamaha parts : YAMAHA YV100X" "
- KLW-M3712-02 protect cover for feeder trolleyKLW-M3712-02 protect cover for feeder trolley www ( dot ) smt-cn ( dot ) com Skype :14786692449 sale (at ) hysmt ( dot ) cn Other yamaha parts :" "
- KLW-M741S-A00 SHAFT,SPAREKLW-M741S-A00 SHAFT,SPARE www ( dot ) smt-cn ( dot ) com Skype :14786692449 sale (at ) hysmt ( dot ) cn Other yamaha parts : No. Part No. Part Name Q'ty" "